R8-PS1 EXTENSION POWER SUPPLY MODULE
Tình trạng: In stock
Contact: 0989649965
R8-PS1 Remote I/O R8 Series EXTENSION POWER SUPPLY MODULE (non-isolated)
Số lượt xem: 1482
Detail
·Some details are not shown. Please refer to specification sheets for all information.
R8-PS1
Remote I/O R8 Series
EXTENSION POWER SUPPLY MODULE
(non-isolated)
Functions & Features
• Inserted between I/O modules and supply the power
• Up to two R8-PS1 use is available
MODEL: R8–PS1-R[1]
ORDERING INFORMATION
• Code number: R8-PS1-R[1]
Specify a code from below for [1].
(e.g. R8-PS1-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
POWER INPUT
DC power
R: 24 V DC
(Operational voltage range: ±10 %; ripple 10 %p-p max.)
[1] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
CAUTION
OUTPUT CURRENT & NUMBER OF CONNECTABLE UNIT
It is NOT available to connect 16 of R8-YV4N to power/network module because of limitation of output current of internal supply. The max. output current for internal supply of power/network module is 1.6 A.
The max. consumption current for internal supply of R8-YV4N is 160 mA.
1.6 (A) < 160 (mA) x 16 = 2.56 (A)
Inserting the R8-PS1 between 10th and 11th R8-YV4N enables to connect 16 of R8-YV4N.
POWER UP
Turn the power on at the same time as the power/network module or turn the R8-PS1 on before the power/network module turned on. If the R8-PS1 is not turned on within 3 seconds after the power/network module is turned on, I/O modules are not correctly recognized
GENERAL SPECIFICATIONS
Connection
•Power input, excitation supply: Tension clamp (Front Twin connection)
Applicable wire size: 0.2 - 1.5 mm2
Stripped length: 10 mm
•Internal bus or internal power: Via connector
Max. number of I/O modules: 16
(Max. consumption current of I/O modules: 1.6 A)
Isolation: Internal bus or internal power or power input to exc. supply to FE1
Power LED: Green light turns on when the power is supplied.
INSTALLATION
Power consumption
•DC: Approx. 11 W 24 V DC (@ internal power max. current 1.6 A)
Internal power supply (power supply for I/O module):
• DC power supply: 5 V DC
• Current capacity: 1.6 A
Excitation supply output (excitation for I/O module)
•DC: 24 V DC ±10 %
•Operational current: 8 A
(From power supply, exitation supply connector, via connector for internal bus, supplied to each I/O module. Power output current consumption must be under operational current.)
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: DIN rail
Weight: 100 g (3.53 oz)
PERFORMANCE
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(internal bus or internal power or power input to exc. supply to FE1)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EN 50581
EXTERNAL VIEW
CONNECTION DIAGRAMS
DIMENSIONS unit: mm (inch)
SCHEMATIC CIRCUITRY
Note: In order to improve EMC performance, bond the FE1 terminal to ground.
Caution: FE1 terminal is NOT a protective conductor terminal.
M-System Co., Ltd.
Products
-
R1MS-GH3 THERMOCOUPLE & DC INPUT MODULE
R1MS-GH3 Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (8 points, isolated)
-
R1M-P4/MSR PC RECORDER
-
R1M-P4 Remote I/O R1M Series
R1M-P4 Remote I/O R1M Series CONTACT I/O MODULE (4 totalized counter inputs, 8 contact inputs and outputs)
-
R1M-J3/MSR PC Recorders R1M Series
R1M-J3/MSR PC Recorders R1M Series PC RECORDER (RTD or potentiometer input, 8 points)
-
R1M-J3 Remote I/O R1M Series
R1M-J3 Remote I/O R1M Series RTD & POTENTIOMETER INPUT MODULE (8 points)
-
R1M-GH/MSR PC Recorders R1M Series
R1M-GH/MSR PC Recorders R1M Series PC RECORDER (thermocouple or DC input, 16 points)
-
R1MS-GH3/MSR PC Recorders R1M Series
R1MS-GH3/MSR PC Recorders R1M Series PC RECORDER
-
R1D-GH2 THERMOCOUPLE & DC INPUT MODULE
R1D-GH2 Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; DeviceNet)
-
R1C-GH THERMOCOUPLE & DC INPUT MODULE
R1C-GH Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.10/Ver.2.00)
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1066938Online: 16