R1C-GH
Remote I/O R1X Series
THERMOCOUPLE & DC INPUT MODULE
(16 points; CC-Link Ver.1.10/Ver.2.00)
Functions & Features
• 16-point thermocouple or DC inputs
• CC-Link interface
• CC-Link Version 1.10 and 2.00 can be switched at the startup
MODEL: R1C-GH2T-[1][2]
ORDERING INFORMATION
• Code number: R1C-GH2T-[1][2]
Specify a code from below for each [1] and [2].
(e.g. R1C-GH2T-M2/Q)
• Specify the specification for option code /Q
(e.g. /C01)
• Use Ordering Information Sheet (No. ESU-5956). Default setting will be used if not otherwise specified.
Factory default setting
Input type: DC Voltage ±5 V
Burnout protection: No burnout
Cold junction compensation: No
FIELD TERMINAL TYPE
T: M3 screw terminals
[1] POWER INPUT
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[2] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
RELATED PRODUCTS
• Resistor module (model: REM3-250)
• R1X configurator software (model: R1CON)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types.
PACKAGE INCLUDES...
• Terminating resistor (110 Ω, 0.5 W)
GENERAL SPECIFICATIONS
Connection
Power input, CC-Link: Euro type connector terminal
(applicable wire size: 0.2 to 2.5 mm2 (AWG24 to 12), stripped length 7 mm)
Input: M3 screw terminals (torque 0.6 N·m)
Configurator: 2.5 dia. miniature jack; RS-232-C level
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (gray)
Isolation: Input to CC-Link (FG) to power
PWR indicator: Green LED blinks in normal conditions.
CC-Link COMMUNICATION
Protocol: CC-Link V1.10 / V 2.00
Cable for comm. link: Specified by Mitsubishi Electric
Required nodes
V. 1.10: 4
V. 2.00: 1 (cyclic expansion: 4)
Station No. setting: Rotary switch
V. 1.10: Rotary switch; 1 – 61
V. 2.00: Rotary switch; 1 – 64
Baud rate setting: Rotary switch
L RUN indicator: Red LED turns on in normal conditions.
L ERR. indicator: Red LED turns on or blinks in an
abnormality.
SD indicator: Red LED turns on when transmitting.
RD indicator: Red LED turns on when receiving.
INPUT SPECIFICATIONS
■ Thermocouple or DC input, 16 points
(Common negative for DC input)
•Measuring range ±20 V, ±5 V, ±1 V: Atten. SW ON (3)
•Measuring range ±0.8 V, ±0.2 V, ±50 mV, ±10m V: Atten. SW OFF (1)
Input resistance: 300 kΩ
Thermocouple types: PR, K, E, J, T, B, R, S, C, N, U, L, P
Sampling rate: 150 millisec./16 points
■ A/D conversion output: 16-bit signed binary (negative range represented by 2’s complements)
Engineering unit value is converted into A/D conversion data as shown below.
Input type & range: A/D data (decimal)
±20 V: ±20000
±5 V: ±5000
±1 V: ±10000
±0.8 V: ±8000
±0.2 V: ±20000
±50 mV: ±5000
±10 mV: ±10000
Thermocouples: Temperature × 10
In order to change input type and range after shipment, the R1X configurator software (model: R1CON) is required.
CC-Link version selector input:
Ver. 1.10 with OFF at the startup.
Ver. 2.00 with ON at the startup.
Dry contact input (ON at detect. level ≤ 1.5 V)
Sensing: approx. 5 V DC, 1 mA
Valid only at the moment of the power supplied to the
module. Firmware version 0B.00 or higher required.
Confirm the firmware version using the R1X configurator
software (model: R1CON) or consult M-System.
INSTALLATION
Power consumption
•AC: Approx. 10 VA
•DC: Approx. 7 W
Operating temperature: -5 to +60°C (23 to 140°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 400 g (0.88 lb)
PERFORMANCE (% of measuring range)
Accuracy
DC input: ±0.3 %
Thermocouple input: See the table on the end of this section.
Cold junction compensation error: ±3°C or ±5.4°F max.
(at 20°C ±10°C or 68°F ±18°F)
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
±0.05 %/°C (±0.03 %/°F) for 10 mV range and T/C B (RH)
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute (input to CC-Link [FG] to power to ground [FG1])
EXTERNAL VIEW
CONNECTION DIAGRAM
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
M-System Co., Ltd.
Products
-
R1MS-GH3 THERMOCOUPLE & DC INPUT MODULE
R1MS-GH3 Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (8 points, isolated)
-
R1M-P4/MSR PC RECORDER
-
R1M-P4 Remote I/O R1M Series
R1M-P4 Remote I/O R1M Series CONTACT I/O MODULE (4 totalized counter inputs, 8 contact inputs and outputs)
-
R1M-J3/MSR PC Recorders R1M Series
R1M-J3/MSR PC Recorders R1M Series PC RECORDER (RTD or potentiometer input, 8 points)
-
R1M-J3 Remote I/O R1M Series
R1M-J3 Remote I/O R1M Series RTD & POTENTIOMETER INPUT MODULE (8 points)
-
R1M-GH/MSR PC Recorders R1M Series
R1M-GH/MSR PC Recorders R1M Series PC RECORDER (thermocouple or DC input, 16 points)
-
R1MS-GH3/MSR PC Recorders R1M Series
R1MS-GH3/MSR PC Recorders R1M Series PC RECORDER
-
R1D-GH2 THERMOCOUPLE & DC INPUT MODULE
R1D-GH2 Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; DeviceNet)
-
R5-YV DC VOLTAGE OUTPUT MODULE
R5-YV Remote I/O R5 Series DC VOLTAGE OUTPUT MODULE
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1034161Online: 4