R5-PS POWER SUPPLY MODULE
Tình trạng: In stock
Contact: 0989649965
R5-PS Remote I/O R5 Series POWER SUPPLY MODULE
Số lượt xem: 1506
Detail
·Some details are not shown. Please refer to specification sheets for all information.
R5-PS
Remote I/O R5 Series
POWER SUPPLY MODULE
MODEL: R5–PS[1][2]
ORDERING INFORMATION
• Code number: R5-PS[1][2]
Specify a code from below for each of [1] and [2].
(e.g. R5-PSR/Q)
• Specify the specification for option code /Q
(e.g. /C01/S01)
[1] POWER INPUT
AC Power
K: 100 – 120 V AC
(Operational voltage range 85 – 132 V, 47 – 66 Hz)
L: 200 – 240 V AC
(Operational voltage range 170 – 264 V, 47 – 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[2] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel
NOTICE
■ RUN CONTACT OUTPUT
• Function of RUN contact output
During a Network Module communicates normally with a master device (PLD or PC etc.), RUN contact output of Power Supply Module turns ON.
• When using with dual redundant communication or two system.
During both Network Module or one of them communicates normally with a master device (PLD or PC etc.), RUN contact output of Power Supply Module turns ON.
• When using R5-PS with redundant or two system.
RUN contact output works in same function for both cases. However, when I/O capacity code of installation base is "05:5 slots (single communication mode)" or "09: 9 slots (single communication mode)", the RUN contact output of Power Supply Module installed in a Extender Power Module Base (model: R5-EX1) is not available.
GENERAL SPECIFICATIONS
Connection
•Power input or RUN contact output: M3.5 screw terminals
(torque 0.8 N·m)
•Internal bus or internal power: Via the Installation Base (model: R5-BS)
Screw terminal: Nickel-plated steel (standard) or stainless steel
Isolation: Internal bus or internal power to power supply to RUN contact output to FG
Power LED: Bi-color (red/amber) LED;
Red when the power is supplied; Amber at RUN contact output ON.
■ RUN CONTACT OUTPUT
Contact turns ON (closed) while data from the host is normally received; OFF (open) with loss of communication for approx. 3 seconds.
Rated load: 250 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 0.5 A (resistive load)
Maximum switching voltage: 250 V AC or 30 V DC
Maximum switching power: 250 VA or 150 W
Minimum load: 1 V DC @ 1 mA
Mechanical life: 2 × 107 cycles (rate 300 cycles/min.) When driving an inductive load, external contact protection and noise quenching recommended.
INSTALLATION
Power consumption
•AC: Approx. 90 VA
•DC: Approx. 45 W or 1.8 A
Output current: 1.5 A continuous at 21 V DC;
(Total current continuously consumed at the network modules and I/O modules must be within 1.5 A.)
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R5-BS) or Extender Power Supply Module Base (R5-EX1)
Weight: 250 g (0.55 lb)
PERFORMANCE
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute (Internal bus or internal power to power input to RUN output to FG)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1, EN 61010-2-201
Measurement Category II (RUN contact output)
Installation Category II (power input)
Pollution Degree 2
Internal power or RUN contact output to power input to FG:
Reinforced insulation (300 V)
Internal power to RUN contact output: Basic insulation (300 V)
EXTERNAL VIEW
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
M-System Co., Ltd.
Products
-
R1MS-GH3 THERMOCOUPLE & DC INPUT MODULE
R1MS-GH3 Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (8 points, isolated)
-
R1M-P4/MSR PC RECORDER
-
R1M-P4 Remote I/O R1M Series
R1M-P4 Remote I/O R1M Series CONTACT I/O MODULE (4 totalized counter inputs, 8 contact inputs and outputs)
-
R1M-J3/MSR PC Recorders R1M Series
R1M-J3/MSR PC Recorders R1M Series PC RECORDER (RTD or potentiometer input, 8 points)
-
R1M-J3 Remote I/O R1M Series
R1M-J3 Remote I/O R1M Series RTD & POTENTIOMETER INPUT MODULE (8 points)
-
R1M-GH/MSR PC Recorders R1M Series
R1M-GH/MSR PC Recorders R1M Series PC RECORDER (thermocouple or DC input, 16 points)
-
R1MS-GH3/MSR PC Recorders R1M Series
R1MS-GH3/MSR PC Recorders R1M Series PC RECORDER
-
R1D-GH2 THERMOCOUPLE & DC INPUT MODULE
R1D-GH2 Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; DeviceNet)
-
R1C-GH THERMOCOUPLE & DC INPUT MODULE
R1C-GH Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.10/Ver.2.00)
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1063910Online: 18