R5-NC2 CC-Link INTERFACE MODULE

Share on FacebookShare on Google+Tweet about this on TwitterShare on LinkedIn

Tình trạng: In stock

Contact: 0989649965

R5-NC2 Remote I/O R5 Series CC-Link INTERFACE MODULE (CC-Link Ver.1.10; for 32-point analog signals)

Số lượt xem: 1595

Detail

·Some details are not shown. Please refer to specification sheets for all information.

R5-NC2

Remote I/O R5 Series

CC-Link INTERFACE MODULE
(CC-Link Ver.1.10; for 32-point analog signals)

MODEL: R5-NC2[1]

ORDERING INFORMATION
• Code number: R5-NC2[1]
Specify a code from below for [1].
 (e.g. R5-NC2/Q)
• Specify the specification for option code /Q
 (e.g. /C01)

[1] OPTIONS
blank: none
/Q: With options (specify the specification)

SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating

RELATED PRODUCTS
• PC configurator software (model: R5CON)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the PC.  Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types.

PACKAGE INCLUDES...
• Terminating resistor (110 Ω, 0.5 W)

GENERAL SPECIFICATIONS
Connection
  CC-Link: Euro type connector terminal
  (Applicable wire size: 0.2 – 2.5 mm(AWG 24 to 12), stripped length 7 mm)
  Internal bus: Via the Installation Base (model: R5-BS)
  Internal power: Via the base (model: R5-BS)
Isolation: CC-Link to internal bus or internal power
RUN indicator: Bi-color (green/red) LED; green in normal communications; red when receiving (Function selected with DIP SW)
ERR indicator: Bi-color (green/red) LED; the green ON/ blinks in communication errors; red when transmitting (Function selected with DIP SW)
Data allocation: Fixed to Mode 2

CC-Link COMMUNICATION
Transmission cable: Approved for CC-Link
CC-Link: Conforms to Version 1.10
Station address: Rotary switch; 1 – 64
Station type: Remote device
Number of occupied stations: 8
(This module incorporates two (2) ASICs for four (4) stations (32 I/O, 16 words) to handle 32-word data. Two (2) remote device stations for four stations each must be assigned for this module to the host PLC.)
Baud rate setting: Rotary switch
156kbps, 625kbps, 2.5Mbps, 5Mbps, 10Mbps

INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R5-BS)
Weight: 100 g (3.53 oz)

PERFORMANCE
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute (CC-Link to internal bus or internal power)

STANDARDS & APPROVALS
EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
RoHS Directive
  EN 50581

EXTERNAL VIEW

COMMUNICATION CABLE CONNECTIONS

TRANSMISSION DATA DESCRIPTIONS
The DIP SW located at the side of the module must be turned OFF except at SW3.
Data Allogcation Mode 2 is used for the R5-NC2. In this mode, two (2) words are assigned for one I/O module regardless of whether the second word area is required or not. For example, discrete I/O modules require only one (1) word, but two (2) words are automatically assigned to these modules.
I/O CAPACITY
A maximum of 16 I/O modules can be mounted per station.

I/O DATA DESCRIPTIONS
The data allocations for typical I/O modules are shown below.
Refer to the manual for each module for detailed data allocations.

EXTERNAL DIMENSIONS unit: mm (inch)

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FG terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.

M-System Co., Ltd.

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1064387
Online: 18
0989649965
Sales@m-system.com.vnFacebook: M-System.com.vnZalo: 0989649965