R5-DC16

Remote I/O R5 Series

DISCRETE OUTPUT MODULE
(open collector output, 16 points)

MODEL: R5–DC16[1][2]

ORDERING INFORMATION
• Code number: R5-DC16[1][2]
Specify a code from below for each of [1] and [2].
  (e.g. R5-DC16W/Q)
• Specify the specification for option code /Q
  (e.g. /C01)

NO. OF CHANNELS
16: 16 points

[1] COMMUNICATION MODE
S: Single
W: Dual

[2] OPTIONS
blank: none
/Q: With options (specify the specification)

SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating

RELATED PRODUCTS
• Cable (model: MCN20)
(in combination with Relay I/O output block, Omron Model: G7TC-OC16)

RELATED PRODUCTS
•Cable with connectors (OMRON)
 250 mm (model: G79-O25C)
 500 mm (model: G79-O50C)
•Connector/terminal block converter (OMRON)
model: XW2D-20G6

GENERAL SPECIFICATIONS
Connection
  Internal bus: Via the Installation Base (model: R5-BS)
  Output: 20-pin connector OMRON model: XG4A-2034
  Internal power: Via the base (model: R5-BS)
Isolation: Output to internal bus or internal power
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
Output status indicator: Red LED; turns on with the output ON.

OUTPUT SPECIFICATIONS
Output: Open collector, 16 points
Commons: All negatives
Rated load
Maximum
: 30 V DC @ 100 mA (resistive load)
Continuous: 30 V DC @ 60 mA (resistive load)
Total current of the output 1 thr. 8 and the output 9 thr. 16 must respectively be 500 mA or less.
Maximum leak current at OFF: 0.01 mA
Saturation voltage: 1 V DC
When driving an inductive load, external contact protection and noise quenching recommended.

INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R5-BS)
Weight: 100 g (3.53 oz)

PERFORMANCE
Data allocation: 1
Response time: ≤ 0.1 sec.
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(output to internal bus or internal power)
2000 V AC @ 1 minute (power input to FG; isolated on the power supply module)

STANDARDS & APPROVALS
EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
RoHS Directive
  EN 50581

FUNCTIONS
Output hold function:
In normal conditions, the module outputs the signal from the preferred bus A.
When an error is detected, the output is switched to the data from the bus B.
If both are in error, the module holds the signal and stands by until one of the communications recovers.
At the startup, it outputs OFF until the communication is established and normal data is received.

EXTERNAL VIEW

CONNECTOR PIN ASSIGNMENT

EXTERNAL DIMENSIONS unit: mm (inch)

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

OUTPUT CONNECTOR

M-System Co., Ltd.

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1064132
Online: 25
0989649965
Sales@m-system.com.vnFacebook: M-System.com.vnZalo: 0989649965