R3Y-PA16 TOTALIZED PULSE INPUT MODULE
Tình trạng: In stock
Contact: 0989649965
R3Y-PA16 Remote I/O R3 Series TOTALIZED PULSE INPUT MODULE (Pi 16 points; connector type)
Số lượt xem: 1642
Detail
·Some details are not shown. Please refer to specification sheets for all information.
R3Y-PA16
Remote I/O R3 Series
TOTALIZED PULSE INPUT MODULE
(Pi 16 points; connector type)
MODEL: R3Y–PA16[1][2]
ORDERING INFORMATION
• Code number: R3Y-PA16[1][2]
Specify a code from below for each [1] and [2].
(e.g. R3Y-PA16W/A/CE/Q)
• Specify the specification for option code /Q
(e.g. /C01/SET)
NO. OF CHANNELS
16: 16
[1] COMMUNICATION MODE
S: Single
W: Dual
[2] OPTIONS (multiple selections)
Excitation
Blank: Internal (negative common)
/A: External (24 V DC, negative common)
Standards & Approvals
blank: Without CE
/CE: CE marking
Other Options
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
(No. ESU-8389)
GENERAL SPECIFICATIONS
Connection
Internal bus: Via the Installation Base (model: R3-BSx)
Input: 40-pin connector (Fujitsu Model FCN-365P040-AU)
Internal power: Via the Installation Base (model: R3-BSx)
Isolation: Input to internal bus or internal power
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with the excitation abnormality;
Green in normal operating conditions.
Input status indicator: Red LED; turns on with the inputs supplied.
Count reset: Via DIP switches on the side
INPUT SPECIFICATIONS
Number of input: 16 points
Input resistance: 6 kΩ
Common: Negative commons, all points
Maximum frequency: 100 Hz (ON/OFF time ≥ 5 msec.)
This unit is designed to be able to accept a frequency up to 100 Hz, however, ‘chattering’ contact must be avoided for accurate measuring of such high frequency. Use mercury relays or similar ones that do not cause any chattering.
Totalized pulse range: 1 – 10000 (‘0’ at reset)
Max. pulse range selectable from 1 to 65535 using the R3CON PC Configurator Software. Refer to the R3CON Users Manual for detailed information.
Count at overflow: Reset and restart at ‘1.’
■ R3-PA16x (internal excitation)
Sensing voltage: 13 V DC (max. 24 V with no load)
ON current: ≥ 1.5 mA (≤ 1.5 kΩ)
OFF current: ≤ 0.75 mA (≥ 18 kΩ)
■ R3-PA16x/A (external excitation)
Sensing voltage: 24 V DC
ON current: ≥ 1.5 mA (≤ 12 kΩ)
OFF current: ≤ 0.75 mA (≥ 36 kΩ)
INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R3-BSx)
Weight: 200 g (0.44 lb)
PERFORMANCE
Data allocation: 16
Current consumption:
R3Y-PA16x: 100 mA
R3Y-PA16x/A: 80 mA
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
(input to internal bus or internal power)
2000 V AC @ 1 minute (power input to FG; isolated on the power supply module)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EN 50581
FUNCTIONS
■ MANUAL COUNT RESET
1) Remove Network Module or its cables and interrupt communication with other devices.
2) Turn ON the Count Reset SW (DIP SW3-1).
3) Return the module to the base and turn the power supply on.
4) ERR LED turns on and the module starts resetting its counter. When the resetting is complete, the LED light turns to green. DO NOT remove the power while the red light is on.The RUN LED starts blinking at the same time.
5) After the green LED is confirmed, turn the power supply off.
6) Turn OFF the Count Reset SW (DIP SW3-1).
7) Return the Network module onto the base and turn the power supply on.
Note: Count Reset SW must be turned OFF after this procedure because the module does not start counting with ON state.
■ REMOTE COUNT RESET INPUT
With the Count Reset Input SW (DIP SW3-3) turned ON, the Pi 16 pulse input can be used to remotely reset the count values.
SW3-3 = OFF: Pi 16 is used as a pulse input.
SW3-3 = ON: Pi 16 is used to reset the count values for the Pi 1 through Pi 15. One pulse supplied at the Pi 16 will be recognized as a reset signal.
■ REMOTE COUNT RESET OPERATION
1) ERR LED turns on (red color) when the reset signal is received.
2) In 1 second, the module starts resetting its counter.
When the resetting is complete, the LED light turns to green.
3) After 1 second, ERR LED turns back to the state before the reset signal has been received.
Note: Reset signals received while the module is processing (1) through (3) are ignored.
EXTERNAL VIEW
DIMENSIONS unit: mm (inch)
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
INPUT CONNECTOR (40-pin)
M-System Co., Ltd.
Products
-
R1MS-GH3 THERMOCOUPLE & DC INPUT MODULE
R1MS-GH3 Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (8 points, isolated)
-
R1M-P4/MSR PC RECORDER
-
R1M-P4 Remote I/O R1M Series
R1M-P4 Remote I/O R1M Series CONTACT I/O MODULE (4 totalized counter inputs, 8 contact inputs and outputs)
-
R1M-J3/MSR PC Recorders R1M Series
R1M-J3/MSR PC Recorders R1M Series PC RECORDER (RTD or potentiometer input, 8 points)
-
R1M-J3 Remote I/O R1M Series
R1M-J3 Remote I/O R1M Series RTD & POTENTIOMETER INPUT MODULE (8 points)
-
R1M-GH/MSR PC Recorders R1M Series
R1M-GH/MSR PC Recorders R1M Series PC RECORDER (thermocouple or DC input, 16 points)
-
R1MS-GH3/MSR PC Recorders R1M Series
R1MS-GH3/MSR PC Recorders R1M Series PC RECORDER
-
R1D-GH2 THERMOCOUPLE & DC INPUT MODULE
R1D-GH2 Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; DeviceNet)
-
R1C-GH THERMOCOUPLE & DC INPUT MODULE
R1C-GH Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.10/Ver.2.00)
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1064592Online: 27