R30YV4 DC VOLTAGE OUTPUT MODULE

Share on FacebookShare on Google+Tweet about this on TwitterShare on LinkedIn

Tình trạng: In stock

Contact: 0989649965

R30YV4 Remote I/O R30 Series DC VOLTAGE OUTPUT MODULE (4 points, isolated)

Số lượt xem: 2039

Detail

·Some details are not shown. Please refer to specification sheets for all information.

R30YV4

Remote I/O R30 Series

DC VOLTAGE OUTPUT MODULE
(4 points, isolated)

Functions & Features
• 4 channels for DC voltage output remote I/O module
• Isolation between output channels
• Output range of each channel is individually adjustable with PC configurator

MODEL: R30YV4S[1]

ORDERING INFORMATION
• Code number: R30YV4S[1]
Specify a code from below for [1].
  (e.g. R30YV4S/Q)
• Specify the specification for option code /Q
  (e.g. /C01/SET)

NO. OF CHANNELS
4: 4

COMMUNICATION MODE
S: Single

[1] OPTIONS
blank: none
/Q: With options (specify the specification)

SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
 (No. ESU-9005)

RELATED PRODUCTS
• PC configurator software (model: R30CFG)
Downloadable at M-System’s web site.
For connecting to PC, use commercially available Mini-B type USB cable. (provided by user)

GENERAL SPECIFICATIONS
Connection
 Internal bus
: Via the Installation Base (model: R30BS)
 Output: M3 separable screw terminal (torque 0.5 N·m)
 Internal power supply: Via the Installation Base (model: R30BS)
Solderless terminal: Refer to the drawing at the end of the section.
   Recommended manufacturer: Japan Solderless Terminal MFG. Co., Ltd., Nichifu Co., Ltd. 
  (Solderless terminals with insulation sleeve do not fit.)
  Applicable wire size: 0.25 to 0.75 mm2
Screw terminal: Nickel-plated steel
Isolation: Output 1 to output 2 to output 3 to output 4 to internal bus or internal power
Output range: Selectable with PC configurator software (model: R30CFG)
Output at the loss of communication: Selectable with PC configurator software (Model: R30CFG, factory default: output hold)
Status indicator LED: RUN, ERR
(refer to the instruction manual)

OUTPUT SPECIFICATIONS
Module type: Analog output, 4 points
Output range: -10 - +10V DC (*), -5 - +5V DC, 0 - 10V DC,
0 - 5V DC, 1 - 5V DC
(*) Factory default
Load resistance: ≥ 100 kΩ
Operational range:
Except -10 to +10 V DC: -15 to +115 % of output range
-10 to +10 V DC: Approx. -11.5 to +11.5 V DC

INSTALLATION
Current consumption: 60 mA
Operating temperature: -10 to +55°C (14 to 131°F)
Storage temperature: -20 to +65°C (-4 to +149°F)
Operating humidity: 10 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R30BS)
Weight: 160 g (0.35 lb)

PERFORMANCE
Conversion accuracy: ±0.1 %
Conversion rate: 10 msec.
Data range: 0 – 10000 of the output range
Data allocation: 4
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Output delay time: ≤ 250 ms (0 - 90 %)
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute (output 1 to output 2 to output 3 to output 4 to internal bus or internal power)
1500 V AC @ 1 minute (power input to FE; isolated by the power supply module)

STANDARDS & APPROVALS
EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
RoHS Directive
  EN 50581

FUNCTIONS
■ Output at the loss of communication
• Output Hold
If the network module is in error, the module holds the signal at error and stands by until the communication recovers.
• Output set value
If the network module is in error, the module holds the signal at error or power up and stands by until the communication recovers. The signal at error or power up is selectable with PC configurator software (Model: R30 CFG)

Not depending on output at the loss of communication setting, when power up the module holds the signal at error or power up and stands by until the normal data is received.

CONFIGURATOR SOFTWARE SETTING
With configurator software, settings shown below are available.
Refer to the software manual of R30CFG for detailed operation.

EXTERNAL VIEW

TERMINAL ASSIGNMENTS

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

M-System Co., Ltd.

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1069159
Online: 27
0989649965