R30PA2 Remote I/O R30 Series TOTALIZED PULSE INPUT MODULE (Pi 2 points, 32 Bits)

Số lượt xem: 2055

Detail

·Some details are not shown. Please refer to specification sheets for all information.

R30PA2

Remote I/O R30 Series

TOTALIZED PULSE INPUT MODULE
(Pi 2 points, 32 Bits)

Functions & Features
• Space-saving remote I/O module of 2 points input pulse counter
• 32-bit binary data

MODEL: R30PA2S[1]

ORDERING INFORMATION
• Code number: R30PA2S[1]
Specify a code from below for [1].
  (e.g. R30PA2S/Q)
• Specify the specification for option code /Q
  (e.g. /C01/SET)

NO. OF CHANNELS
2: 2

COMMUNICATION MODE
S: Single

[1] OPTIONS
Other Options
blank: none
/Q: Option other than the above (specify the specification)

SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
 (No. ESU-9022)

RELATED PRODUCTS
• Interface Module
  Model: R30NECT1 (firmware version V1.04.10 or higher)
  Model: R30NCIE1 (firmware version V1.01.13 or higher)
• Paperless Recorder
  Model: TR30 (firmware version V1.05 or higher)
• PC configurator software (model: R30CFG)
Downloadable at M-System’s web site.
For connecting to PC, use commercially available Mini-B type USB cable. (provided by user)

GENERAL SPECIFICATIONS
Connection
 Internal bus
: Via the Installation Base (model: R30BS)
 Input: M3 separable screw terminal (torque 0.5 N·m)
 Internal power supply: Via the Installation Base (model: R30BS)
Solderless terminal: Refer to the drawing at the end of the section.
   Recommended manufacturer: Japan Solderless Terminal MFG. Co., Ltd., Nichifu Co., Ltd. 
  (Solderless terminals with insulation sleeve do not fit.)
  Applicable wire size: 0.25 to 0.75 mm2
Screw terminal: Nickel-plated steel
Isolation: Input or reset input or external power to internal bus or internal power
Status indicator LEDs: RUN, ERR
Input status indicator LEDs: Green LED; turns on with input ON
(Refer to the instruction manual.)
Count reset: by inputting one pulse to the reset input terminal, or from host PC/PLC
Count preset: settable from host PC/PLC, or with PC configurator software

INPUT SPECIFICATIONS
Module type: Pulse input, 2 points
Common: Positive or negative common (NPN/PNP), common per 2 points
■ Contact Input / Reset Input
Open collector input (NPN, PNP)
 Rated input voltage: 24 V DC ±10 %; ripple 5 %p-p max.
 ON voltage/current: ≥ 16 V DC (input to common) / 
 ≥ 3.7 mA
 OFF voltage/current: ≤ 5 V DC (input to common) / ≤ 1 mA
Voltage Pulse Input
 ON voltage/current: ≥ 16 V DC (input to common) / 
 ≥ 3.7 mA
 OFF voltage/current: ≤ 5 V DC (input to common) / ≤ 1 mA
Input current: ≤ 5.5 mA per point at 24 V DC
Input resistance: Approx. 4.4 kΩ
ON delay: ≤ 2.0 msec.
OFF delay: ≤ 2.0 msec.
Max input frequency: 100 Hz
Minimum pulse width time requirement: 5 msec. (for both ON and OFF)
Totalized pulse range: 0 to 4,294,967,295 (0 only when the counter is reset)
Max pulse range: 1 to 4,294,967,295
(factory setting: 4,294,967,295)
Count at overflow: 0 or 1 (factory setting: 0)

INSTALLATION
Current consumption: 30 mA max.
Operating temperature: -10 to +55°C (14 to 131°F)
Storage temperature: -20 to +65°C (-4 to +149°F)
Operating humidity: 10 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R30BS)
Weight: 150 g (0.33 lb)

PERFORMANCE
Data allocation: 4
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(input or reset input or external power to internal bus or internal power)
1500 V AC @ 1 minute (power to FG; isolated on the power supply module)

STANDARDS & APPROVALS
EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
RoHS Directive
  EN 50581

CONFIGURATOR SOFTWARE SETTING
With configurator software, settings shown below are available.
Refer to the software manual of R30CFG for detailed operation.

EXTERNAL VIEW

TERMINAL ASSIGNMENTS

DATA ALLOCATION

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

M-System Co., Ltd.

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1066798
Online: 19
0989649965
Sales@m-system.com.vnFacebook: M-System.com.vnZalo: 0989649965