R30NOUA1 Remote I/O R30 Series NETWORK MODULE (OPC UA)
Số lượt xem: 2048
Detail
·Some details are not shown. Please refer to specification sheets for all information.
R30NOUA1
Remote I/O R30 Series
NETWORK MODULE
(OPC UA)
Functions & Features
• Interchanges analog or discrete I/O signals with the OPC UA network.
MODEL: R30NOUA1[1]
ORDERING INFORMATION
• Code number: R30NOUA1[1]
Specify a code from below for [1].
(e.g. R30NOUA1/Q)
• Specify the specification for option code /Q
(e.g. /C01)
[1] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
NOTICE
R30NOUA1 cannot be used in combination with R3 series I/O modules for extension.
RELATED PRODUCTS
• PC configurator software (model: R30CFG)
Downloadable at M-System’s web site.
For connecting to PC, use commercially available Mini-B type USB cable. (provided by user)
GENERAL SPECIFICATIONS
Connection
OPC UA: RJ-45 connector
Internal bus: Via the Installation Base (model: R30BS)
Internal power: Via the Installation Base (model: R30BS)
Housing material: Flame-resistant resin (gray)
Isolation: OPC UA to internal bus or internal power
Calendar clock: Year (4 digits), month, date, day, hour, minute, second
Internal bus communication cycle: Approx. 1 msec.
Indicator LED: RUN, D LINK, ERR
(Refer to the instruction manual for details.)
OPC UA COMMUNICATION
Connection: Ethernet IPv4
Baud rate: 10/100 Mbps
Transmission media: 10BASE-T (STP, Category 5), 100BASE-TX (STP, Category 5e)
Max. length of fieldbus segment: 100 meters
Status indicator LEDs: DPX, LNK
IP address: 192.168.0.1 (factory setting)
Server/Client: OPC UA server (client function not supported)
Encode: UA Binary (UA XML not supported)
Protocol: UA TCP (SOAP/HTTP not supported)
TCP port No.: 4840 (fixed)
Max. number of clients: 4
Encryption: None
Signature: None
Server authentication: None (X059 Certificates not supported)
User authentication: Anonymous (no authentication); Username (authentication by user name and password)
Server type: DA server (Data access)
INSTALLATION
Current consumption: 115 mA
Operating temperature: 0 to 50°C (32 to 122°F)
Storage temperature: -10 to +60°C (14 to +140°F)
Operating humidity: 10 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R30BS)
Weight: 160 g (0.35 lb)
PERFORMANCE
Calendar clock: (with battery backup)
Accuracy: Monthly deviation 2 minutes at 25°C
Back up period: Approx. 2 years at 25°C
Battery: Primary lithium battery (non-removable)
(In order to prevent battery drain, battery back up is OFF at factory default. Turn it ON prior to start using.)
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(OPC UA to internal bus or internal power)
1500 V AC @ 1 minute (power input to FE; isolated on the power supply module)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EN 50581
EXTERNAL VIEW
EXTERNAL DIMENSIONS unit: mm (inch)
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
M-System Co., Ltd.
Products
-
R1MS-GH3 THERMOCOUPLE & DC INPUT MODULE
R1MS-GH3 Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (8 points, isolated)
-
R1M-P4/MSR PC RECORDER
-
R1M-P4 Remote I/O R1M Series
R1M-P4 Remote I/O R1M Series CONTACT I/O MODULE (4 totalized counter inputs, 8 contact inputs and outputs)
-
R1M-J3/MSR PC Recorders R1M Series
R1M-J3/MSR PC Recorders R1M Series PC RECORDER (RTD or potentiometer input, 8 points)
-
R1M-J3 Remote I/O R1M Series
R1M-J3 Remote I/O R1M Series RTD & POTENTIOMETER INPUT MODULE (8 points)
-
R1M-GH/MSR PC Recorders R1M Series
R1M-GH/MSR PC Recorders R1M Series PC RECORDER (thermocouple or DC input, 16 points)
-
R1MS-GH3/MSR PC Recorders R1M Series
R1MS-GH3/MSR PC Recorders R1M Series PC RECORDER
-
R1D-GH2 THERMOCOUPLE & DC INPUT MODULE
R1D-GH2 Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; DeviceNet)
-
R1C-GH THERMOCOUPLE & DC INPUT MODULE
R1C-GH Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.10/Ver.2.00)
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1067724Online: 22