R30EBS Remote I/O R30 Series INSTALLATION BASE (R3 I/O module extension use)
Số lượt xem: 2067
Detail
·Some details are not shown. Please refer to specification sheets for all information.
R30EBS
Remote I/O R30 Series
INSTALLATION BASE (R3 I/O module extension use)
MODEL: R30EBS[1][2]
ORDERING INFORMATION
• Code number: R30EBS[1][2]
Specify a code from below for each [1] and [2].
(e.g. R30EBS08/Q)
• Specify the specification for option code /Q
(e.g. /C01)
[1] NUMBER OF I/O SLOTS
04: 4 slots
08: 8 slots
[2] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
Only solder side of the main PWB is coated.
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
FUNCTIONS & FEATURES
Installation base to add R3 series I/O modules to R30 modules. Install with R30BS to extend. The type and number of slot of available R3 series I/O module is limited by power supply module and network module. Refer to the specification and instruction manual for each module.
CAUTION
The internal bus communication period for R3 series I/O modules installed in R30EBS is as follows.
Internal bus communication period = 6 msec. x number of I/O module + 10 msec. (Data update period of main CPU)
Example: Four R3 series I/O modules
6 msec. x 4 + 10 msec. = 34 msec.
Even R30EBS is installed, the internal bus communication period of R30 series remains approx. 1 msec.
GENERAL SPECIFICATIONS
Capacity:
R30EBS04: I/O module, 4 slots
R30EBS08: I/O module, 8 slots
INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Storage temperature: -20 to +65°C (-4 to +149°F)
Operating humidity: 10 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Surface or DIN rail
Weight (Without modules mounted)
R30EBS04: approx. 150 g (0.33 lb)
R30EBS08: approx. 280 g (0.62 lb)
PERFORMANCE
Dielectric strength: 1500 V AC @ 1 minute (Internal power or internal bus to FE; isolated on the power supply module)
EXTERNAL VIEW
Use in combination with R30BS. Mount the R3 I/O Modules from the left end (I/O 1) to the right.
DIMENSIONS unit: mm (inch)
MOUNTING REQUIREMENTS unit: mm (inch)
M-System Co., Ltd.
Products
-
R1MS-GH3 THERMOCOUPLE & DC INPUT MODULE
R1MS-GH3 Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (8 points, isolated)
-
R1M-P4/MSR PC RECORDER
-
R1M-P4 Remote I/O R1M Series
R1M-P4 Remote I/O R1M Series CONTACT I/O MODULE (4 totalized counter inputs, 8 contact inputs and outputs)
-
R1M-J3/MSR PC Recorders R1M Series
R1M-J3/MSR PC Recorders R1M Series PC RECORDER (RTD or potentiometer input, 8 points)
-
R1M-J3 Remote I/O R1M Series
R1M-J3 Remote I/O R1M Series RTD & POTENTIOMETER INPUT MODULE (8 points)
-
R1M-GH/MSR PC Recorders R1M Series
R1M-GH/MSR PC Recorders R1M Series PC RECORDER (thermocouple or DC input, 16 points)
-
R1MS-GH3/MSR PC Recorders R1M Series
R1MS-GH3/MSR PC Recorders R1M Series PC RECORDER
-
R1D-GH2 THERMOCOUPLE & DC INPUT MODULE
R1D-GH2 Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; DeviceNet)
-
R1C-GH THERMOCOUPLE & DC INPUT MODULE
R1C-GH Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.10/Ver.2.00)
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1067681Online: 19