R30BS INSTALLATION BASE
Tình trạng: In stock
Contact: 0989649965
R30BS Remote I/O R30 Series INSTALLATION BASE
Số lượt xem: 2123
Detail
·Some details are not shown. Please refer to specification sheets for all information.
R30BS
Remote I/O R30 Series
INSTALLATION BASE
Functions & Features
· Installation base dedicated to Remote I/O R30 Series, Paperless Recorder TR30 Series and Field Logger DL30 Series
MODEL: R30BS[1][2]
ORDERING INFORMATION
• Code number: R30BS[1][2]
Specify a code from below for each [1] and [2].
(e.g. R30BS16/Q)
• Specify the specification for option code /Q
(e.g. /C01)
[1] NUMBER OF SLOTS
00: 0 slot
02: 2 slots
04: 4 slots
08: 8 slots
12: 12 slots
16: 16 slots
[2] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
Only solder side of the main PWB is coated.
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
GENERAL SPECIFICATIONS
Capacity:
R30BS00: I/O module, 0 slot (Model: TR30, DL30 single use)
R30BS02: I/O module, 2 slots
R30BS04: I/O module, 4 slots
R30BS08: I/O module, 8 slots
R30BS12: I/O module, 12 slots
R30BS16: I/O module, 16 slots
INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Storage temperature: -20 to +65°C (-4 to +149°F)
Operating humidity: 10 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Surface or DIN rail
Weight (Without modules mounted)
R30BS00: approx. 50 g (1.76 oz)
R30BS02: approx. 100 g (0.22 lb)
R30BS04: approx. 160 g (0.35 lb)
R30BS08: approx. 260 g (0.57 lb)
R30BS12: approx. 360 g (0.79 lb)
R30BS16: approx. 470 g (1.04 lb)
PERFORMANCE
Dielectric strength: 1500 V AC @ 1 minute (Internal power or internal bus to FE; isolated on the power supply module)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EN 50581
EXTERNAL VIEW
Mount the power supply module and network module on the dedicated slots (PWR and COM), and do not mount on I/O slots. PWR slot is on the left end and COM slot is on the immediate right of PWR slot. The I/O slots are numbered in the ascending order starting from the one on the immediate right of the network module (slot 1, slot 2...).
For model: TR30 or DL30, mount it on the PWR and COM slot.
DIMENSIONS unit: mm (inch)
MOUNTING REQUIREMENTS unit: mm (inch)
M-System Co., Ltd.
Products
-
R1MS-GH3 THERMOCOUPLE & DC INPUT MODULE
R1MS-GH3 Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (8 points, isolated)
-
R1M-P4/MSR PC RECORDER
-
R1M-P4 Remote I/O R1M Series
R1M-P4 Remote I/O R1M Series CONTACT I/O MODULE (4 totalized counter inputs, 8 contact inputs and outputs)
-
R1M-J3/MSR PC Recorders R1M Series
R1M-J3/MSR PC Recorders R1M Series PC RECORDER (RTD or potentiometer input, 8 points)
-
R1M-J3 Remote I/O R1M Series
R1M-J3 Remote I/O R1M Series RTD & POTENTIOMETER INPUT MODULE (8 points)
-
R1M-GH/MSR PC Recorders R1M Series
R1M-GH/MSR PC Recorders R1M Series PC RECORDER (thermocouple or DC input, 16 points)
-
R1MS-GH3/MSR PC Recorders R1M Series
R1MS-GH3/MSR PC Recorders R1M Series PC RECORDER
-
R1D-GH2 THERMOCOUPLE & DC INPUT MODULE
R1D-GH2 Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; DeviceNet)
-
R1C-GH THERMOCOUPLE & DC INPUT MODULE
R1C-GH Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.10/Ver.2.00)
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1079697Online: 20