R30 SERIES GENERAL SPECIFICATIONS
Tình trạng: In stock
Contact: 0989649965
R30 Remote I/O R30 Series R30 SERIES GENERAL SPECIFICATIONS
Số lượt xem: 1651
Detail
·Some details are not shown. Please refer to specification sheets for all information.
R30
Remote I/O R30 Series
R30 SERIES GENERAL SPECIFICATIONS
Functions & Features
• Remote I/O modules which interchange analog or digital I/O signals with fieldbus (EtherCAT etc.).
ORDERING INFORMATION
Refer to the specifications of the respective modules for details.
NETWORK MODULE: R30[1]
Refer to the specifications of each module for details.
[1] MODULE TYPE
NCIE1: CC-Link IE Field network
NE1: Ethernet (Modbus/TCP)
NECT1: EtherCAT
NOUA1: OPC UA
INTERFACE I/O MODULE: R30[1]S
Refer to the specifications of each module for details.
[1] MODULE TYPE
GCIE1: CC-Link IE Field network
GECT1: EtherCAT
COMMUNICATION MODE
S: Single
BASE: R30[1][2]
Refer to the specifications of each base for details.
[1] MODULE TYPE
BS: Base
[2] NUMBER OF SLOTS
02: 2 slots
04: 4 slots
08: 8 slots
12: 12 slots
16: 16 slots
R3 I/O MODULE EXTENSION BASE: R30[1][2]
Refer to the specifications of each base for details.
[1] TYPE
TYPE
EBS: R3 I/O Module extension base
[2] NUMBER OF SLOTS
04: 4 slots
08: 8 slots
I/O MODULES: R30[1][2]
Refer to the specifications of each module for details.
[1] MODULE TYPE
• Analog Input
SV2: DC voltage/current input module, 2 points
SV4: DC voltage/current input module, 4 points
SVF4: DC voltage/current input module, high speed, 4 points
TS4: Thermocouple input module, 4 points
RS4: RTD input module, 4 points
MS4: Potentiometer input module, 4 points
CT4E: AC current input module, 4 points
US2: Universal input module, 2 points
US4: Universal input module, 4 points
• Analog Output
YV4: DC voltage output module, 4 points
YS4: DC current output module, 4 points (CE not available)
• Pulse Input
PA2: Totalized pulse input module, 2 points
• Discrete Input
XN16A: Discrete input module, 16 points
• Discrete Output
YN16A: NPN transistor output module, 16 points
YN16C: PNP transistor output module, 16 points
[2] COMMUNICATION MODE
S: Single
POWER SUPPLY MODULE: R30[1]-[2]
Refer to the specifications of each module for details.
[1] MODULE TYPE
PS1: Power supply module (current capacity 750 mA)
[2] POWER INPUT
• DC power
R: 24 V DC
BLANK FILLER MODULE: R30[1]
Refer to the specifications of each module for details.
[1] MODULE TYPE
DM: Blank filler module
FUNCTIONS & FEATURES
The R30 Series Remote I/O consists of a network module, I/O modules, a power supply module and an installation base in free combinations and doesn't require complicated settings.
Internal high speed communication bus provides fast I/O responsce.
■ NETWORK MODULE
Converts data between open network fieldbus and I/O modules, functioning as a gateway.
■ INTERFACE I/O MODULE
It is available to handle the data on the open network fieldbus (CC-Link IE Field, etc.) with different protocol interface module. (Gateway module)
■ I/O MODULE
Transmits input data to the network module or outputs data received from the network module.
■ POWER SUPPLY MODULE
Converts DC power input for use in the network module and I/O modules.
■ BASE
Supplys internal power converted by the power supply module to the network module and I/O modules. Connects the network module and internal communication bus of I/O modules.
The power supply module and network module each have a dedicated slot to mount. Up to 16 I/O modules can be mounted.
CAUTION
• The internal bus communication period for R3 series I/O modules installed on the R30EBS is as follows.
Internal bus communication period = 6 msec. x number of I/O module + 10 msec. (Data update period of main CPU)
Example: Four R3 I/O modules
6 msec. x 4 + 10 msec. = 34 msec.
Even when the R30EBS is mounted to the R30BS, the internal bus communication period of R30 series is kept to approx. 1 msec.
RELATED PRODUCTS
• PC configurator software (model: R30CFG)
• PC configurator software (model: R3CON)(Only for using R30EBS)
Downloadable at M-System’s web site.
For connecting to PC, use commercially available Mini-B type USB cable. (provided by user)
GENERAL SPECIFICATIONS
Connection: Depends upon the type of modules. Refer to the specifications for the respective modules.
Housing material: Flame-resistant resin (gray)
■ INTERNAL COMMUNICATION BUS
Read rate: Approx. 1 msec.
■ DATA CONVERSION
Depends upon the type of I/O modules. Refer to the specification for the respective I/O modules.
INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Storage temperature: -20 to +65°C (-4 to +149°F)
Operating humidity: 10 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Surface or DIN rail
Weight: Refer to the specifications of the respective modules.
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EN 50581
CURRENT CONSUMPTION
BASIC CONFIGURATIONS
EXTERNAL DIMENSIONS unit: mm (inch)
MOUNTING REQUIREMENTS unit: mm (inch)
M-System Co., Ltd.
Products
-
R1MS-GH3 THERMOCOUPLE & DC INPUT MODULE
R1MS-GH3 Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (8 points, isolated)
-
R1M-P4/MSR PC RECORDER
-
R1M-P4 Remote I/O R1M Series
R1M-P4 Remote I/O R1M Series CONTACT I/O MODULE (4 totalized counter inputs, 8 contact inputs and outputs)
-
R1M-J3/MSR PC Recorders R1M Series
R1M-J3/MSR PC Recorders R1M Series PC RECORDER (RTD or potentiometer input, 8 points)
-
R1M-J3 Remote I/O R1M Series
R1M-J3 Remote I/O R1M Series RTD & POTENTIOMETER INPUT MODULE (8 points)
-
R1M-GH/MSR PC Recorders R1M Series
R1M-GH/MSR PC Recorders R1M Series PC RECORDER (thermocouple or DC input, 16 points)
-
R1MS-GH3/MSR PC Recorders R1M Series
R1MS-GH3/MSR PC Recorders R1M Series PC RECORDER
-
R1D-GH2 THERMOCOUPLE & DC INPUT MODULE
R1D-GH2 Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; DeviceNet)
-
R1C-GH THERMOCOUPLE & DC INPUT MODULE
R1C-GH Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.10/Ver.2.00)
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1079712Online: 19