R3-GM1 MODBUS INTERFACE MODULE

Share on FacebookShare on Google+Tweet about this on TwitterShare on LinkedIn

Tình trạng: In stock

Contact: 0989649965

R3-GM1 Remote I/O R3 Series MODBUS INTERFACE MODULE

Số lượt xem: 1628

Detail

·Some details are not shown. Please refer to specification sheets for all information.

R3-GM1

Remote I/O R3 Series

MODBUS INTERFACE MODULE

Functions & Features
• Enables other protocol interface modules to communicate with Modbus data (gateway).
• Recognized as an analog I/O mixed module by other protocol interface modules.
• Used as Modbus slave device like R3-NM1.
Typical Applications
• A gateway for CC-Link and Modbus.
 

MODEL: R3-GM1S[1]

ORDERING INFORMATION
• Code number: R3-GM1S[1]
Specify a code from below for [1].
  (e.g. R3-GM1S/CE/Q)
• Specify the specification for option code /Q
  (e.g. /C01)

COMMUNICATION MODE
S: Single

[1] OPTIONS (multiple selections)
Standards & Approvals
blank: Without CE
/CE: CE marking
Other Options
blank: none
/Q: Option other than the above (specify the specification)

SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating

RELATED PRODUCTS
• Interface module (model: R3-NC1, R3-NC3, R3-NDx, 
R3-NE1, R3-NFL1, R3-NM4, R3-NP1)
Firmware version V2.00 or later
• Interface module (model: R3-NM3, R3-NML3)
Firmware version V1.00 or later
• Paperless recorder (model: 73VR3100)

PACKAGE INCLUDES...
• Terminating resistor (110 Ω, 0.25 W)

GENERAL SPECIFICATIONS
Connection
  Modbus
: Euro type connector terminal
  (applicable wire size: 0.2 to 2.5 mm2, stripped length 7 mm)
  Internal bus: Via the Installation Base
  (model: R3-BSx)
  Internal Power: Via the Installation Base
  (model: R3-BSx)
  RUN contact output: M3 separable screw terminal
  (torque 0.5 N·m)
Screw terminal: Nickel-plated steel
Isolation: Modbus to internal bus or internal power to RUN contact output
RUN indicator: Bi-color (green/red) LED; green when Modbus communication and the field bus built-in R3 interface module are in normal; red when receiving data. Select with DIP switch.
ERR indicator: Bi-color (green/red) LED; the green ON/blinks in communication errors (OFF with wire breakdown; blinks with setting errors); red when transmitting data. Select with DIP switch.
Module allocation: Set with the side DIP switch.
 RUN CONTACT OUTPUT
RUN contact: Turns on while the green RUN LED is ON (only when Modbus communication and the field bus built-in the interface module are in normal).
Rated load: 250 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 0.5 A (resistive load)
(Less than 50 V AC to conform with EU Directive)
Maximum switching voltage: 250 V AC or 30 V DC
Maximum switching power: 250 VA or 150 W
Minimum load: 1 V DC @ 1 mA
Mechanical life: 2 × 107 cycles (300 cycles/min.)
When driving an inductive load, external contact protection and noise quenching recommended.

MODBUS COMMUNICATION
Standard: Conforms to TIA/EIA-485-A
Transmission distance: 500 meters max.
Transmission media: Shielded twisted-pair cable
(CPEV-S 0.9 dia.)
Transmission setting: DIP switch (front)
  Data mode: RTU (Binary) or ASCII
  Parity: None, even or odd
  Baud rate: 4800, 9600, 19.2 k, 38.4 k (bps)
Node address: Rotary switch; 01 – F7

INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R3-BSx)
Weight: 200 g (0.44 lb)

PERFORMANCE
Data allocation: 16 × n (Module allocation: 1 to 8)
Current consumption: 100 mA
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(Modbus to internal bus or internal power to RUN contact output)
2000 V AC @ 1 minute (power input to FG; isolated on the power supply module)

STANDARDS & APPROVALS
EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
RoHS Directive
  EN 50581

EXTERNAL VIEW

COMMUNICATION CABLE CONNECTIONS

MODBUS FUNCTION CODES & SUPPORTED CODES

MODBUS I/O ASSIGNMENT

TRANSMISSION DATA DESCRIPTIONS
Use the DIP SW located at the side of the module to specify module allocation.
1 module is equivalent to 1 I/O module with 16 words analog input and 16 words analog output. Max. 8 modules (128 words input, 128 words output) transmission is available. R3-GM1 seems as if max. 8 I/O modules are mounted to 8 slots via Modbus.
The input of the module is processed as follows.
  Modbus Communication --> R3-GM1 Module --> R3 Base --> R3 Communication Module
In responding to the input, the output (Holding Register) command becomes valid via Modbus communication, and the input (Input Register) command is valid in the output.
Note: Do not mount any modules in the slots which are occupied by virtual modules. If a real I/O module is mounted in the slot, an internal bus error occurs. Max. 16 real I/O modules and virtual modules are available. The interface module can not read the data for more than 16 modules.

I/O DATA DESCRIPTIONS

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

SYSTEM CONFIGURATION EXAMPLES
In the following system configuration, Modbus data is converted to CC-Link data via this unit which is used as a gateway.

M-System Co., Ltd.

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1068431
Online: 17
0989649965
Sales@m-system.com.vnFacebook: M-System.com.vnZalo: 0989649965