R3-GE1 ETHERNET INTERFACE MODULE

Share on FacebookShare on Google+Tweet about this on TwitterShare on LinkedIn

Tình trạng: In stock

Contact: 0989649965

R3-GE1 Remote I/O R3 Series ETHERNET INTERFACE MODULE (Modbus/TCP)

Số lượt xem: 1588

Detail

·Some details are not shown. Please refer to specification sheets for all information.

R3-GE1

Remote I/O R3 Series

ETHERNET INTERFACE MODULE
(Modbus/TCP)

Functions & Features
• Enables other protocol interface modules to communicate with Modbus/TCP data (gateway).
• Recognized as an analog I/O mixed module by other protocol interface modules.
• Used as Modbus/TCP slave device like R3-NE1.
Typical Applications
• A gateway for CC-Link and Modbus.
 

MODEL: R3-GE1S[1]

ORDERING INFORMATION
• Code number: R3-GE1S[1]
Specify a code from below for [1].
  (e.g. R3-GE1S/CE/Q)
• Specify the specification for option code /Q
  (e.g. /C01)

COMMUNICATION MODE
S: Single

[1] OPTIONS (multiple selections)
Standards & Approvals
blank: Without CE
/CE: CE marking
Other Options
blank: none
/Q: Option other than the above (specify the specification)

SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating

RELATED PRODUCTS
• PC configurator software (model: R3CON)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the PC.  Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types.
• Interface module (model: R3-NC1, R3-NC3, R3-NDx, 
R3-NM1, R3-NM4, R3-NFL1, R3-NP1)
Firmware version V2.00 or later
• Interface module (model: R3-NM3, R3-NML3)
Firmware version V1.00 or later
• Paperless recorder (model: 73VR3100)

GENERAL SPECIFICATIONS
Connection
Ethernet
: RJ-45 Modular Jack
Internal bus: Via the Installation Base (model: R3-BSx)
Internal power: Via the Installation Base (model: R3-BSx)
RUN contact output: M3 separable screw terminal
(torque 0.5 N·m)
Screw terminal: Nickel-plated steel
Isolation: Ethernet to internal bus or internal power to RUN contact output
RUN indicator: Bi-color (green/red) LED; green when Modbus/ TCP communication and the field bus built-in R3 interface module are in normal; red when receiving data. Select with DIP SW3.
ERR indicator: Bi-color (green/red) LED; the green ON/blinks in communication errors (OFF with wire breakdown; blinks with setting errors.); red when transmitting data. Select with DIP SW3.
Module allocation: Set with the side DIP switch.
 RUN CONTACT OUTPUT
RUN contact: Turns on while the green RUN LED is ON (only when Modbus/TCP communication and the field bus built-in the interface module are in normal).
Rated load: 250 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 0.5 A (resistive load)
(Less than 50 V AC to conform with EU Directive)
Maximum switching voltage: 250 V AC or 30 V DC
Maximum switching power: 250 VA or 150 W
Minimum load: 1 V DC @ 1 mA
Mechanical life: 2 × 107 cycles (300 cycles/min.)
When driving an inductive load, external contact protection and noise quenching recommended.

ETHERNET COMMUNICATION
Communication Standard: IEEE 802.3u
Transmission: 10BASE-T, 100BASE-TX
Baud rate: 10/100 Mbps (Auto Negotiation function)
Protocol: Modbus/TCP
Data: RTU (Binary)
Max. number of socket connections: 2
Transmission media: 10BASE-T (STP, Category 5) 100BASE-TX (STP, Category 5e)
Max. length of fieldbus segment: 100 meters
Ethernet indicator LED: LINK, DPLX, LINK10, LINK100, COL
IP address: 192.168.0.1 (factory setting);
Selectable with PC Configurator Software (model: R3CON)
Port No.: 502

INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R3-BSx)
Weight: 200 g (0.44 lb)

PERFORMANCE
Data allocation: 16 × n (Module allocation: 1 to 8)
Current consumption: 100 mA
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(Ethernet to internal bus or internal power to RUN contact output)
2000 V AC @ 1 minute (power input to FG; isolated on the power supply module)

STANDARDS & APPROVALS
EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
RoHS Directive
  EN 50581

EXTERNAL VIEW

MODBUS FUNCTION CODES & SUPPORTED CODES

MODBUS I/O ASSIGNMENT

TRANSMISSION DATA DESCRIPTIONS
Use the DIP SW located at the side of the module to specify module allocation.
1 module is equivalent to 1 I/O module with 16 words analog input and 16 words analog output. Max. 8 modules (128 words input, 128 words output) transmission is available. This module seems as if max. 8 I/O modules are mounted to 8 slots via Modbus/TCP.
The input of the module is processed as follows.
[Modbus Communication] --> [R3-GE1 Module] --> [R3 Base] --> [R3 Communication Module]
In responding to the input, the output (Holding Register) command becomes valid via Modbus/TCP communication, and the input (Input Register) command is valid in the output.
Note: Do not mount any modules in the slots which are occupied by virtual modules. If a real I/O module is mounted in the slot, an internal bus error occurs. Max. 16 real I/O modules and virtual modules are available. The interface module can not read the data for more than 16 modules.

I/O DATA DESCRIPTIONS

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

SYSTEM CONFIGURATION EXAMPLES
In the following system configuration, Modbus/TCP data is converted to CC-Link data via this module which is used as a gateway.

M-System Co., Ltd.

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1069281
Online: 20
0989649965
Sales@m-system.com.vnFacebook: M-System.com.vnZalo: 0989649965