R3-GC1 CC-Link INTERFACE MODULE
Tình trạng: In stock
Contact: 0989649965
R3-GC1 Remote I/O R3 Series CC-Link INTERFACE MODULE (CC-Link Ver.1.10/Ver.2.00)
Số lượt xem: 1608
Detail
·Some details are not shown. Please refer to specification sheets for all information.
R3-GC1
Remote I/O R3 Series
CC-Link INTERFACE MODULE
(CC-Link Ver.1.10/Ver.2.00)
Functions & Features
• Enables other protocol interface modules to communicate with CC-Link data (gateway).
• Recognized as an analog I/O mixed module by other protocol interface modules.
Typical Applications
• A gateway for CC-Link and Modbus.
MODEL: R3-GC1S[1]
ORDERING INFORMATION
• Code number: R3-GC1S[1]
Specify a code from below for [1].
(e.g. R3-GC1S/CE/Q)
• Specify the specification for option code /Q
(e.g. /C01)
COMMUNICATION MODE
S: Single
[1] OPTIONS (multiple selections)
Standards & Approvals
blank: Without CE
/CE: CE marking
Other Options
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
RELATED PRODUCTS
• Interface module (model: R3-NE1, R3-NM1, R3-NM4,
R3-NDx, R3-NFL1, R3-NP1)
Firmware version V2.00 or later
• Interface module (model: R3-NM3, R3-NML3)
Firmware version V1.00 or later
• Paperless recorder (model: 73VR3100)
PACKAGE INCLUDES...
• Terminating resistor (110 Ω, 0.5 W)
GENERAL SPECIFICATIONS
Connection
Network: Euro type connector terminal
(applicable wire size: 0.2 to 2.5 mm2, stripped length 7 mm)
Internal bus: Via the Installation Base
(model: R3-BSx)
Internal Power: Via the Installation Base
(model: R3-BSx)
RUN contact output: M3 separable screw terminal
(torque 0.5 N·m)
Screw terminal: Nickel-plated steel
Isolation: CC-Link to internal bus or internal power to RUN contact output
RUN indicator: Bi-color (green/red) LED; green when CC-Link communication and the field bus builtin R3 interface module are in normal; red when receiving data. Select with DIP SW3.
ERR indicator: Bi-color (green/red) LED; the green ON/blinks in communication errors (OFF with wire breakdown; blinks with setting errors.); red when transmitting data. Select with DIP SW3.
■ RUN CONTACT OUTPUT
RUN contact: Turns on while the green RUN LED is ON
(only when CC-Link communication and the
field bus built-in the interface module are in normal).
Rated load: 250 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 0.5 A (resistive load)
(Less than 50 V AC to conform with EU Directive)
Maximum switching voltage: 250 V AC or 30 V DC
Maximum switching power: 250 VA or 150 W
Minimum load: 1 V DC @ 1 mA
Mechanical life: 2 × 107 cycles (300 cycles/min.)
When driving an inductive load, external contact protection and noise quenching recommended.
CC-Link COMMUNICATION
CC-Link: Both Version 1.10 and Version 2.00 are available.
Select the version with DIP SW3.
Cyclic expansion: 2, 4, 8 folds (Function selected with DIP
SW)
Station No. setting: Rotary switch; 1 – 64
Baud rate setting: Rotary switch
156kbps, 625kbps, 2.5Mbps, 5Mbps, 10Mbps
Station type: Remote device station
Required nodes: 4
Ver.1.10: (128 I/O points, 16 words)
Ver.2.00: (112 I/O points, 16 words) × m (m = expanded
cyclic setting)
Transmission cable: Approved for CC-Link
INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R3-BSx)
Weight: 200 g (0.44 lb)
PERFORMANCE
Data allocation
Ver.1.10: 16
Ver.2.00: 16 × m (m = expanded cyclic setting)
Current consumption: 120 mA
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(CC-Link to internal bus or internal power to RUN contact output)
2000 V AC @ 1 minute (power input to FG; isolated on the power supply module)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EN 50581
EXTERNAL VIEW
COMMUNICATION CABLE CONNECTIONS
TRANSMISSION DATA DESCRIPTIONS
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
SYSTEM CONFIGURATION EXAMPLES
In the following system configuration, PC Recorder software captures the CC-Link data via R3-GC1 which is used as a gateway.
M-System Co., Ltd.
Products
-
R1MS-GH3 THERMOCOUPLE & DC INPUT MODULE
R1MS-GH3 Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (8 points, isolated)
-
R1M-P4/MSR PC RECORDER
-
R1M-P4 Remote I/O R1M Series
R1M-P4 Remote I/O R1M Series CONTACT I/O MODULE (4 totalized counter inputs, 8 contact inputs and outputs)
-
R1M-J3/MSR PC Recorders R1M Series
R1M-J3/MSR PC Recorders R1M Series PC RECORDER (RTD or potentiometer input, 8 points)
-
R1M-J3 Remote I/O R1M Series
R1M-J3 Remote I/O R1M Series RTD & POTENTIOMETER INPUT MODULE (8 points)
-
R1M-GH/MSR PC Recorders R1M Series
R1M-GH/MSR PC Recorders R1M Series PC RECORDER (thermocouple or DC input, 16 points)
-
R1MS-GH3/MSR PC Recorders R1M Series
R1MS-GH3/MSR PC Recorders R1M Series PC RECORDER
-
R1D-GH2 THERMOCOUPLE & DC INPUT MODULE
R1D-GH2 Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; DeviceNet)
-
R1C-GH THERMOCOUPLE & DC INPUT MODULE
R1C-GH Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.10/Ver.2.00)
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1082457Online: 12