R7L LonWorks I/O MODULE
Tình trạng: In stock
Contact: 0989649965
R7L Remote I/O R7 Series LonWorks I/O MODULE
Số lượt xem: 1124
Detail
·Some details are not shown. Please refer to specification sheets for all information.
R7L
Remote I/O R7 Series
LonWorks I/O MODULE
ORDERING INFORMATION
• Basic module: R7L-[1]-AR[2]
Specify a code from below for each [1] and [2].
(e.g. R7L-DC16A-AR/Q)
• Specify the specification for option code /Q
(e.g. /C01)
• Extension module: R7L-[1][2]
Specify a code from below for each [1] and [2].
(e.g. R7L-EC16A/Q)
• Specify the specification for option code /Q
(e.g. /C01)
MODEL: R7L-[1]-AR[2]
[1] I/O TYPE
DA16: Discrete input, 16 points
DC16A: NPN transistor output, 16 points
(One-shot pulse output is available.)
DC16B: PNP transistor output, 16 points
(One-shot pulse output is available.)
DAC16: PNP discrete input, 8 points
NPN transistor output, 8 points
(One-shot pulse output is available.)
SV4: DC voltage/current input (10 V/20 mA), 4 points
TS4: Thermocouple input, 4 points
RS4: RTD input, 4 points
YV2: DC voltage output, 2 points
YS2: DC current output, 2 points
RR8: Remote control relay control output, 8 points
R7L-DA16 and -DAC16 can accept totalized pulse input with no need of input extension module. Other modules need extension module.
POWER INPUT
Universal
AR: 24 V AC/24 V DC
(Operational voltage range: 24 V AC±10 %,50/60Hz/
24 V DC±10 %, ripple 10 %p-p max.)
[2] OPTIONS
blank: none
/Q: With options (specify the specification)
EXTENSION MODULE: R7L–[1][2]
[1] I/O TYPE
EA8: Discrete input, 8 points
EA16: Discrete input, 16 points
EC8A: NPN transistor output, 8 points
EC16A: NPN transistor output, 16 points
EC8B: PNP transistor output, 8 points
EC16B: PNP transistor output, 16 points
[2] OPTIONS
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
FUNCTIONS & FEATURES
The R7L interfaces analog and discrete I/O signals with a PC via LonWorks.
A ‘basic’ module can be attached with an ‘extension’ module. By combining two modules, single station can handle mixed analog and discrete signals, 32-point discrete inputs, 32-point discrete outputs, 16-point discrete I/Os and other combinations of signals.
Single module can handle multiple Functional Blocks, not only the discrete I/O, but also the pulse count input, one-shot output, scaling, alarm output, and so forth.
Input sensor type (thermocouple, RTD) and range can be selected using the LNS Plug-in Software (model: R7LPLG).
RELATED PRODUCTS
• XIF File (Device Interface File)
XIF file is used to define a LonWorks device when programmed on LonMaker.
• LNS Plug-in Software (model: R7LPLG)
XIF files and LNS Plug-in Software are downloadable at M-System's web site.
LonWorks SYSTEM REQUIREMENTS
• LonMaker Turbo Edition Ver.3.2 or higher + LonMaker
Turbo Service Pack 4.0 or higher
• LonMark Resource File Ver.13 or higher
GENERAL SPECIFICATIONS
■ Common Specifications
Power input:
24 V AC ±10 % (50 / 60 Hz)
24 V DC ±10 %; ripple 10 %p-p max.
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @1 minute
(between isolated circuits)
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Storage temperature: -20 to +65°C (-4 to +149°F)
Mounting: DIN rail (35 mm wide)
Connection: M3 separable screw terminals
(torque 0.5 N·m)
Screw terminal material: Nickel-plated steel
Solderless terminal: Refer to the drawing at the end of the section.
Recommended manufacturer: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd
Applicable wire size: 0.25 to 1.65 mm2 (AWG22 to 16)
Housing material: Flame-resistant resin (gray)
Status indicator: PWR, ONLINE, ERR, TX/RX, SVCE
(Refer to the instruction manual for details)
■ Current Consumption & Weight
Current consumption at 24 V AC / 24 V DC
R7L-DA16: 70 mA / 40 mA; 200 g (7.1 oz)
R7L-DC16A: 80 mA / 50 mA; 200 g (7.1 oz)
R7L-DC16B: 80 mA / 50 mA; 200 g (7.1 oz)
R7L-DAC16: 75 mA / 45 mA; 200 g (7.1 oz)
R7L-SV4: 80 mA / 50 mA; 200 g (7.1 oz)
R7L-TS4: 85 mA / 50 mA; 200 g (7.1 oz)
R7L-RS4: 85 mA / 50 mA; 200 g (7.1 oz)
R7L-YV2: 110 mA / 70 mA; 200 g (7.1 oz)
R7L-YS2: 180 mA / 110 mA; 200 g (7.1 oz)
R7L-RR8: 75 mA / 50 mA; 200 g (7.1 oz)
R7L-EA8: 15 mA / 10 mA; 90 g (3.2 oz)
R7L-EA16: 30 mA / 20 mA; 150 g (5.3 oz)
R7L-EC8A: 15 mA / 10 mA; 90 g (3.2 oz)
R7L-EC16A: 30 mA 20 mA; 150 g (5.3 oz)
R7L-EC8B: 15 mA / 10 mA; 90 g (3.2 oz)
R7L-EC16B: 30 mA / 20 mA; 150 g (5.3 oz)
■ I/O Status Indicator
• Discrete I/O
Discrete I/O modules have LED indicators showing I/O signal status.
• Analog I/O
Analog I/O modules have LED indicators showing network variable status assigned to fbLED.
(Refer to the instruction manual for details)
■ Service Switch
Used to identify the node in LonWorks network configuration.
■ Reset Switch
Used to reset the Neuron Chip. Press the switch behind the front cover to reset.
Control functions are halted while completing resetting and restarting. Confirm no danger before conducting resetting.
LonWorks COMMUNICATION
Neuron Chip: FT3120 (NeuronID printed in numeric and bar code [peel-off code 39 format] under the specification marking on the product; two sticker labels attached)
Transceiver: FT-X1 (equivalent to FTT10A)
Transmission speed: 78 kbps
Twisted-pair cable
Distance, free topology: 500 meters
Max. 64 nodes/channel
EXTERNAL VIEW
CONNECTION DIAGRAMS
DATA CONVERSION
EXTENSION MODULE
A ‘basic’ module can be attached with one ‘extension’ module. The extension module is powered from the basic module.
By combining two modules, single station can handle mixed analog and discrete signals.
Settings of the extension module are handled by Functional Blocks of the basic module. Refer to the instruction manual of the basic module for more information.
■ OUTPUT AT THE LOSS OF COMMUNICATION
The extension module is set to ‘Hold Output’ by factory default setting. The LNS Plug-in Software (model: R7LPLG) is used to change the setting to ‘Reset Output.’
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
M-System Co., Ltd.
Products
-
FAMCL-01 CC-Link MASTER MODULE
FAMCL-01 Remote I/O FAM Series CC-Link MASTER MODULE (Yokogawa Electric PLC use)
-
R5-MS POTENTIOMETER INPUT MODULE
R5-MS Remote I/O R5 Series POTENTIOMETER INPUT MODULE
-
R8-SS2 DC CURRENT INPUT MODULE
R8-SS2 Remote I/O R8 Series DC CURRENT INPUT MODULE (2 points, isolated)
-
R3-SS8 DC CURRENT INPUT MODULE
R3-SS8 Remote I/O R3 Series DC CURRENT INPUT MODULE (8 points, isolated)
-
R3-RS8 RTD INPUT MODULE
R3-RS8 Remote I/O R3 Series RTD INPUT MODULE (8 points, isolated)
-
R3-DC32A DISCRETE OUTPUT MODULE
R3-DC32A Remote I/O R3 Series DISCRETE OUTPUT MODULE (Do 32 points; open collector)
-
R30SV4 DC VOLTAGE/CURRENT INPUT MODULE
R30SV4 Remote I/O R30 Series DC VOLTAGE/CURRENT INPUT MODULE (4 points, isolated)
-
R3-DC16C DISCRETE OUTPUT MODULE
R3-DC16C Remote I/O R3 Series DISCRETE OUTPUT MODULE (PNP transistor output, 16 points)
-
R3-MS4 POTENTIOMETER INPUT MODULE
R3-MS4 Remote I/O R3 Series POTENTIOMETER INPUT MODULE (4 points, isolated)
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1061379Online: 18