MDP-LWA LIGHTNING SURGE PROTECTOR FOR LonWorks
Tình trạng: In stock
Contact: 0989649965
Số lượt xem: 1099
Detail
·Some details are not shown. Please refer to specification sheets for all information.
MDP-LWA
Lightning Surge Protectors for
Electronics Equipment M-RESTER
LIGHTNING SURGE PROTECTOR FOR
LonWorks
(FTT-10A)
Functions & Features
• Designed specifically for the network
• No interruption of transmission signal by unplugging the head element module
MODEL: MDP–LWA[1]
ORDERING INFORMATION
• Code number: MDP-LWA[1]
Specify a code from below for [1].
(e.g. MDP-LWA/A33/Q)
• Specify the specification for option code /Q
(e.g. /C01)
[1] OPTIONS (multiple selections)
DIN Rail Mounting Adapter
blank: Without
/A33: With adapter (model A-33)
Other Options
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
APPLICABLE NETWORK
LonWorks FTT-10A network
This unit is not applicable to LonWorks Link Power network.
GENERAL SPECIFICATIONS
Construction: Plug-in
Connection: M4 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (black)
INSTALLATION
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 100 g (0.22 lb), standard; 125 g (0.28 lb), with DIN rail mounting adapter
PERFORMANCE
Max. continuous operating voltage (Uc):
Line to line: ±1.5 V
Line to earth: ±100 V
SHLD to earth: ±160 V
Voltage protection level (Up):
• @ 2 kV (1 kA)
Line to line: ±40 V
Line to earth: ±350 V
SHLD to earth: ±650 V
Response time:
Line to line: ≤ 4 nsec.
Line or SHLD to earth: ≤ 20 nsec.
Leakage current:
Line to line: ≤ 0.15 mA @ ±1.5 V
Line to earth: ≤ 20 μA @ ±100 V
SHLD to earth: ≤ ±20 μA @ ±160 V
Max. discharge current (Imax): 5000 A (8 / 20 μs)
Nominal current (IN): 100 mA
Internal series resistance: ≤ 3.3 Ω including return
Capacitance @ 1 MHz:
Line to line: ≤ 200 pF
Line to earth: ≤ 200 pF
SHLD to earth: ≤ 30 pF
Input attenuation: -1 dB or less @ DC to 100 kHz, Z0 = 50 Ω
Surge protection: IEC 61643-21 Categories C1, C2
CONNECTION EXAMPLES
GROUNDING
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
MOUNTING REQUIREMENTS unit: mm (inch)
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
M-System Co., Ltd.
Products
-
MDCAT-NC LIGHTNING SURGE PROTECTOR FOR CC-Link IE Field Network
-
MDP-4R LIGHTNING SURGE PROTECTOR FOR RS-485 / RS-422
-
MDW5-4R LIGHTNING SURGE PROTECTOR FOR RS-485 / RS-422
-
MDCAT-A LIGHTNING SURGE PROTECTOR FOR ETHERNET
-
MDCAT LIGHTNING SURGE PROTECTOR FOR ETHERNET
-
MDM5E-A LIGHTNING SURGE PROTECTOR FOR ETHERNET
-
MD74R LIGHTNING SURGE PROTECTOR FOR RS-485 / RS-422
-
MDW5-CC LIGHTNING SURGE PROTECTOR FOR CC-Link
-
MD7FB LIGHTNING SURGE PROTECTOR FOR FOUNDATION Fieldbus
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1056685Online: 26