MDM2AT Lightning Surge Protectors for Electronics Equipment M-RESTER

Share on FacebookShare on Google+Tweet about this on TwitterShare on LinkedIn

Tình trạng: In stock

Contact: 0989649965

Số lượt xem: 1027

Detail

·Some details are not shown. Please refer to specification sheets for all information.

MDM2AT

Lightning Surge Protectors for
Electronics Equipment M-RESTER

LIGHTNING SURGE PROTECTOR FOR
STANDARD SIGNAL LINE & PULSE USE
(life monitor, 24 V, 48 V or 65 V DC line voltage, photovoltaic system, instrument shelter)

Functions & Features
• Designed specifically for 4 – 20 mA DC and pulse signal lines
• Absorbs surges only without affecting instrumentation signal
• Life monitor function helps you to decide when you should replace the surge protector; reduces time and effort for maintenance and prevents downtime
• LED display and alarm output indicate the degradation and life span of the surge protection circuits
• Wide range of operating temperature from -20 to +70°C
(-4 to +158°F)

MODEL: MDM2AT–[1]–[2]

ORDERING INFORMATION
• Code number: MDM2AT-[1]-[2]
Specify a code from below for each of [1] and [2].
  (e.g. MDM2AT-24-M2)

[1] NOMINAL VOLTAGE
24: 24 V DC
65: 48 V or 65 V DC

[2] POWER INPUT
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
 47 – 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)

GENERAL SPECIFICATIONS
Construction: Plug-in
Connection: M3 screw terminals (torque 0.8 N·m)
Housing material: Flame-resistant resin (black)
Alarm indicators
  PWR
: The green LED turns on while the power is supplied.
  ALM: Tricolor LED (green/amber/red)
· Remains off when the power supply is first turned on.
· Green: The unit has received one or more surges.
· Amber: Replacement is recommended.
· Red: The life span has ended.
Degradation judged: When the leakage current at the voltage limiter exceed approx. 7.5 μA.
Life time judged: When the number of discharges of the discharge element reaches the expected life span.
Alarm output: The N.C. contact is on when the life span of the discharge elements has ended, when the voltage limiter has degraded, and/or when the power supply is removed.
  Rating: 125 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 1 A (resistive load)
  Maximum switching voltage: 125 V AC or 110 V DC
  Maximum switching power: 62.5 VA or 30 W
  Minimum load: 5 V DC @ 1 mA

INSTALLATION
Power consumption
•AC: ≥ 2.3 VA at 100 V
 ≥ 3.5 VA at 200 V
 ≥ 4.6 VA at 240 V
•DC: ≥ 1.7 W
Operating temperature: -20 to +70°C (-4 to +158°F)
Storage temperature: -30 to +70°C (-22 to +158°F)
Operating humidity: 10 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 150 g (0.33 lb)

PERFORMANCE
Max. continuous operating voltage (Uc):
 Line to line: 30 V (24 V DC use), 70 V (48 V or 65 V DC use)
 Line to earth: ±140 V
Voltage protection level (Up):
 Line to line: 45 V max. (24 V DC use), 100 V max.
 (48 V or 65 V DC use) 
 Line to earth: ±650 V max.
Response time: ≤ 0.1 μsec.
Leakage current:
  Line to line: ≤ 5 μA @ max. voltage  
  Line to earth: ≤ 5 μA @ max. voltage
Discharge current capacity: 5000 A (8 / 20 μsec.)
Max. load current: 100 mA
Insulation resistance: ≥ 100 MΩ with 500 V DC
(surge protector circuit to alarm output to power)
Dielectric strength: 2000 V AC @ 1 minute (surge protector circuit to alarm output to power)
Internal series resistance: 20 Ω ±10 % (including return)

STANDARDS & APPROVALS
EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
Low Voltage Directive
  EN 61010-1
  Measurement Category II (alarm output)
  Installation Category II (power)
  Pollution degree 2
  Surge protector circuit to power:
  Reinforced insulation (300 V)
RoHS Directive
  EN 50581

CAUTION
Before replacing the unit, make sure to turn off the power supply for safety.  Other factors such like an alarm system connected to the line should also be considered.
The life monitoring circuit remains alive by the internal backup circuit even when the external power supply is removed.  The LED is turned off in that case.

CONNECTION EXAMPLES

GROUNDING

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

M-System Co., Ltd.

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1034222
Online: 7
0989649965
Sales@m-system.com.vnFacebook: M-System.com.vnZalo: 0989649965