MD6T-65

Lightning Surge Protectors for
Electronics Equipment M-RESTER

LIGHTNING SURGE PROTECTOR FOR
STANDARD SIGNAL LINE & PULSE USE
(conduit mount, weather-proof; 65 V DC line voltage)

Functions & Features
• Designed specifically for 4 – 20 mA DC and pulse signal line including both 4-wire and 2-wire transmitters
• Direct mount in a wiring conduit of outdoor
enclosures
• Absorbs surges only without affecting instrumentation signal

MODEL: MD6T–65–[1][2][3]

ORDERING INFORMATION
• Code number: MD6T–65–[1][2][3]
Specify a code from below for each of [1] through [3].
  (e.g. MD6T-65-00B)
For the safety approval code 4, specify the product’s destination country using Ordering Information Sheet (No. ESU-8284).

[1] SAFETY APPROVAL
0: None
4: ATEX flameproof

[2] WIRING CONDUIT
0: G 1/2 (Not selectable for ATEX flameproof approval)
1: 1/2 NPT
2: M20 × 1.5

[3] BODY MATERIAL
B: Brass
S: Stainless steel

CAUTION
The packing of the cable gland must be separate from the body. Choose an appropriate one for the environment in which the surge protector is used.

GENERAL SPECIFICATIONS
Degree of protection: IP65
Wiring conduit: See ‘Ordering information.’
Connection
  Cable side
: Euro type terminal block (Applicable wire size:
  0.14 – 1.5 mm2 (AWG26 – 16) for both stranded and solid
  wires; stripped length 6 mm)
  Equipment side: Leadwires (leadwire diameter AWG20 for grounding; AWG22 for the protected equipment)
Body material: Nickel-plated brass or stainless steel 316

INSTALLATION
Operating temperature: -40 to +85°C (-40 to +185°F)
(See Safety Parameters for use in a hazardous
location.)

Mounting: Screwed into an electrical conduit of outdoor enclosures
Weight: 500 g (1.1 lb)

PERFORMANCE
Discharge voltage (peack voltage)
  Line to line: 70 V min.
  Line to ground: ±160 V min.
Max. surge voltage
  Line to line: 100 V max. 
  Line to ground: ±650 V max.
(The maximum voltage that could pass through the surge protector. Protected equipment must be able to withstand this voltage for a very short time period.)
Response time:
 Line to line: ≤ 4 nsec.
 Line to ground: ≤ 20 nsec.
Leakage current:
  Line to line: ≤ 5 μA @ 70 V DC
  Line to ground: ≤ 5 μA @ ±160 V DC
Discharge current capacity: 10000 A (8/ 20 μsec.)
Max. load current: 100 mA
Internal series resistance: Approx. 22 Ω including return
Max. line voltage 
  Without safety approval: 70 V DC
  With safety approval: 66 V DC
Capacitance @ 1 kHz:
 Line to line:  ≤ 2500 pF
 Line to ground: ≤ 100 pF

STANDARDS & APPROVALS
EU conformity:
ATEX Directive 
  Ex d EN 60079-1
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
RoHS Directive
  EN 50581
Safety approval:

SAFETY PARAMETERS
Operating temperature:
  T5 -40 to +80°C
  T6 -40 to +75°C
    -40 to +75°C for ATEX flameproof

CONNECTION EXAMPLES

EXTERNAL DIMENSIONS unit: mm (inch)

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

M-System Co., Ltd.

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1059274
Online: 14
0989649965
Sales@m-system.com.vnFacebook: M-System.com.vnZalo: 0989649965