MATPH Lightning Surge Protectors for Electronics Equipment M-RESTER SURGE PROTECTOR FOR PHOTOVOLTAIC SYSTEM

Số lượt xem: 1484

Detail

·Some details are not shown. Please refer to specification sheets for all information.

MATPH

Lightning Surge Protectors for
Electronics Equipment M-RESTER

SURGE PROTECTOR FOR PHOTOVOLTAIC SYSTEM
(750V DC,1000V DC USE)

Functions & Features
• Surge protection for photovoltaic array and power conditioner.
• High discharge current capacity 20 kA
• Degraded head element is automatically separated from the power lines by the incorporated thermal breaker, and the LED lamp (turns off) and the relay contact alerts the failure status.
• Breakdown of the surge protector remotely detected with the alarm output
• Photovoltaic system's resistance to earth is measurable without removing the SPD due to spark gap employed between line and earth.
 

MODEL: MATPH–[1]M[2]

ORDERING INFORMATION
• Code number: MATPH-[1]M[2]
 Specify a code from below for each [1] and [2].
 (e.g.MATPH-1000MA)

[1] OPERATIONAL VOLTAGE
750: 750 V DC
1000: 1000 V DC

MAXIMUM DISCHARGE CURRENT
M: 20kA (8/20 μsec.)

[2] ALARM OUTPUT
A: With
Y: Without

GENERAL SPECIFICATIONS
Construction: Standalone; terminal access at the front
Degree of protection: IP20 (If the solderless terminals are covered with insulation tubes.)
Surge protection type: One-port combination type SPD
Connection
  Line: M5 screw terminal (torque: 2.5 N·m)
  Alarm output: Tension clamp
Applicable wire size
 Line: See the drawing below.
 Alarm output: 0.13 to 1.5 mm2, stripped length 8 mm
Screw terminal
 Line
: Nickel-plated steel
 Alarm output: Tin-plated copper alloy
Housing material: Flame-resistant resin (black)
Alarm output: Trips when the thermal breaker operates. (N.C. contact)
Rated load:
250 V AC @50 mA (resistive load)
24 V DC @50 mA (resistive load)
Safety function: Thermal breaker incorporated
Monitor LED: Green LED turns on during normal conditions (100 V DC to operational votage), and turns off during failure condition, power off and the thermal breaker operating.

INSTALLATION
Operating temperature: -25 to +80°C (-13 to +176°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: DIN Rail
Weight: 200 g (0.44 lb)

PERFORMANCE
Max. continuous operating voltage (Uc, Line to line):
 750 V DC for MATPH-750
 1000 V DC for MATPH-1000
Discharge voltage (Line to earth): 500 V DC
Voltage protection level (Up):
• MATPH-750
 Line to line: 2.5 kV (@In) 
 Line to earth: 1.8 kV (@In)
• MATPH-1000
 Line to line: 3.3 kV (@In)
 Line to earth:  2.1 kV  (@In)
Maximum discharge current (Imax): 20 kA (8/ 20 μs)
Nominal discharge current (In): 10 kA (8/ 20 μs)
Response time:
 Line to line: ≤ 4 nsec.
 Line to earth: ≤ 20 nsec.
Leakage current: ≤ 1 mA
Insulation resistance: ≥ 100 MΩ with 500 V DC (line to alarm output)
Dielectric strength: 2000 V AC @ 1 minute (line to alarm output)
Surge protection: IEC 61643-1 Class II
                             EN 61643-11 Class II

STANDARDS & APPROVALS
Refer to the manuals to comply with the standards.
EU conformity:
Low Voltage Directive
  EN 61643-11
RoHS Directive
  EN 50581

CONNECTION EXAMPLES

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)

SCHEMATIC CIRCUITRY

M-System Co., Ltd.

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1084493
Online: 17
0989649965
Sales@m-system.com.vnFacebook: M-System.com.vnZalo: 0989649965