27HU 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Share on FacebookShare on Google+Tweet about this on TwitterShare on LinkedIn

Tình trạng: In stock

Contact: 0989649965

27HU 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER DC mV, V & mA, T/C, RTD and resistance input 8-35 Vdc powered (max. 28 V approved) ATEX Zone 0 approval FM Class I, Div. 1 & Zone 0 approval

Số lượt xem: 1305

Detail

27HU 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
(HART communication)

Functions & Features
• Universal input: DC mV, T/C, RTD and resistance
• High accuracy
• HART communication
• Intrinsically safe approval
• Suitable for Functional Safety applications up to SIL2
• Programming via hand-held communicator or via PC
• A wide variety of T/C and RTD types
• User’s temperature table can be used
• Self diagnostics
• Ultra-low temp. drift option (20 ppm/°C typ.)
• CE marking (conforms to ATEX and EMC)

MODEL: 27HU–[1][2]

ORDERING INFORMATION
• Code number: 27HU-[1][2]
Specify a code from below for each [1] and [2].
(e.g. 27HU-2/L)
Use Ordering Information Sheet (No. ESU-7651). Factory standard setting will be used if not otherwise specified.
Specify the country in which the product is to be used with the Safety Approval code 2.

[1] SAFETY APPROVAL
0: None
1: FM intrinsically safe
2: CENELEC intrinsic safety (ATEX)

[2] OPTIONS
Temperature Drift
Blank: Standard (temp. coefficient 0.015%/°C)
/L: Ultra-low temperature drift
  (temp. coefficient 0.002%/°C typ., 0.005%/°C max.)

RELATED PRODUCTS
• USB interface Bell202 modem (model: COP-HU)
Usable in ‘non-hazardous’ area only.
• Hand-held communicator
• PC configurator software (model: 27HUCFG)
Downloadable at M-System’s web site.

GENERAL SPECIFICATIONS
Construction: Sensor head-mounting
Connection: M3 screw terminals (torque 0.5 N·m)
Screw terminal: Nickel-plated brass
Housing material: Flame-resistant resin (black)
Isolation: Input to output
User-configurable items:
· Input sensor type and numbers
· Number of wires (RTD & resistance)
· Input range (inverted range selectable)
· Burnout
· Output limits (Upper / Lower)
· Damping time (factory set to 0)
· Cold junction compensation (T/C; internal or external
 sensor selectable)
· Linearization
· Sensor calibration
· Output calibration
· HART communication mode
Refer to the HART setup manual or the PC configurator users manual for the detail.

HART COMMUNICATION
Protocol: HART communication protocol
HART address range: 0 – 15 (factory set to 0)
Transmission speed: 1200 bps
Digital current: Approx. 1 mAp-p when communicating
Character format: 1 Start Bit, 8 Data Bits, 1 Odd Parity Bit,
1 Stop Bit
Distance: 1.5 km (0.9 miles)
HART communication mode: Master-Slave Mode and Burst Mode (factory set to Master-Slave)
HART network mode: Point-to-Point Mode and Multi-drop Mode; automatically set to Multi-drop Mode when the address is set to other than 0.

INPUT SPECIFICATIONS
The input is factory set for use with K thermocouple, single input, 0 to 100°C, internal CJC sensor.
See Table 1 for the available input type, the minimum span and the maximum range.
DC mV (dual input available)
Input resistance:
≥ 1 MΩ
Thermocouple (dual input available)
Input resistance:
≥ 1 MΩ
Burnout sensing: 33 μA
External CJC sensor type: Pt 100
RTD (2-wire, 3-wire or 4-wire)
Input resistance:
≥ 1 MΩ
Excitation: 0.2 mA
Allowable leadwire resistance: Max. 10 Ω per wire
Resistance (2-wire, 3-wire or 4-wire)
Input resistance:
≥ 1 MΩ
Excitation: 0.2 mA
Allowable leadwire resistance: Max. 10 Ω per wire

OUTPUT SPECIFICATIONS
Output range: 4 – 20 mA DC
Operational range: 3.75 – 23 mA
Load resistance vs. supply voltage:
Load Resistance (Ω) = (Supply Voltage (V) – 8 (V))
÷ 0.023 (A)      (including leadwire resistance)
Burnout: 3.75 – 3.8 mA or 21.5 – 23 mA
(factory set to 23 mA)
Upper output limit proportional to the input:
20 – 21.5 mA (factory set to 21.5 mA)
Lower output limit proportional to the input:
3.8 – 4 mA (factory set to 3.8 mA)
Update time: 440 msec. (660 msec. with dual input)
Output characteristics for dual input:
Average or Differential selectable

INSTALLATION
Supply voltage
 · 8 – 35 V DC (non-approved)
 · 8 – 28 V DC (approved)
Operating temperature: -40 to +85°C (-40 to +185°F)
(See Safety Parameters for use in a hazardous
location.)

Operating humidity: 0 to 95 %RH (non-condensing)
Mounting: Head-mounting (DIN type B head)
Weight: 50 g (1.76 oz)

PERFORMANCE
Accuracy: See Table 1.
Cold junction compensation accuracy: ±0.5°C (±0.9°F) with internal CJC sensor
Response time: ≤ 2 sec. (0 – 90 %) with damping time
set to 0 and when not communicating via HART.
Supply voltage effect: ±0.005 % of span/V
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @1 minute (input to output)
Safety integrity level according to IEC 61508: Suitable for use in a safety instrumented system up to SIL2 (together with sensor) if appropriate safety instructions are observed. Consult M-System.

STANDARDS & APPROVALS
EU conformity:
ATEX Directive 
  Ex ia EN 60079-11
EMC Directive 
  EN 61326-1
RoHS Directive
  EN 50581
Safety approval:
FM: Intrinsically safe
  Class I, Division 1, Groups A, B, C and D
  Class I, Zone 0, AEx ia IIC (US)
  Class I, Zone 0, Ex ia IIC (Canada)
  T4, T5 and T6
  (Class 3610, ANSI/ISA 60079-11,
  CAN/CSA-C22.2 No. 157,
  CAN/CSA-C22.2 No. 60079-11)

SAFETY PARAMETERS
Operating temperature
For CENELEC (ATEX) / FM:
  T4: -40 to +80°C
  T5: -40 to +60°C
  T6: -40 to +45°C
Ex-data:
• Output circuit
  Ui (Vmax): 30 V DC
  Ii (Imax): 96 mA DC
  Pi (Pmax): 720 mW
  Ci: 1 nF
  Li: 0 mH
• Sensor circuit
  Uo (Voc): 30 V DC
  Io (Isc): 24 mA DC
  Po: 180 mW
  Co (Ca): 50 nF
  Lo (La): 40 mH

INPUT TYPE, RANGE & ACCURACY

DIMENSIONS unit: mm (inch)

MOUNTING REQUIREMENTS unit: mm (inch)

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

M-System Co., Ltd.

M-System Việt Nam

Email: Sales@m-system.com.vn

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1059847
Online: 19
0989649965