Head-mounted Two-wire Signal Conditioners 26RS
Tình trạng: In stock
Contact: 0989649965
26RS RTS Transmiiter
Head-mounted Two-wire Signal Conditioners 26RS
Số lượt xem: 3673
Detail
26RS Head-mounted Two-wire Signal Conditioners 26-UNIT
RTD TRANSMITTER
(isolated)
Functions & Features
• Accepts direct input from an RTD and provides a standard 4 – 20 mA DC signal
• Linearization and burnout
• Wide operating temperature range suitable for harsh environments
Typical Applications
• Mounting in a sensor connection head minimizes noise effect and signal degradation
MODEL: 26RS–[1][2]
ORDERING INFORMATION
• Code number: 26RS-[1][2]
Specify a code from below for each [1] and [2].
(e.g. 26RS-4/K/BL)
• Temperature range (e.g. 0 – 100°C)
[1] INPUT RTD (2- or 3-wire)
1: JPt 100 (JIS ’89)
(Usable range: -100 to +500°C, -148 to +932°F, min.span: 50°C, 90°F)
3: Pt 100 (JIS ’89)
(Usable range: -100 to +650°C, -148 to +1202°F, min.span: 50°C, 90°F)
4: Pt 100 (JIS ’97, IEC)
(Usable range: -100 to +850°C, -148 to +1562°F, min.span: 50°C, 90°F)
5: Pt 50Ω (JIS ’81)
(Usable range: -100 to +500°C, -148 to +932°F, min.span: 100°C, 180°F)
6: Ni 508.4 Ω
(Usable range: -50 to +200°C, -58 to +392°F; min.span: 30°C, 54°F)
Note: Consult M-System for 2-wire RTD
[2] OPTIONS (multiple selections)
Response Time (0 – 90 %)
blank: Standard (≤ 0.5 sec.)
/K: Fast Response (Approx. 25 msec.)
Burnout
blank: Upscale burnout
Products
-
B5RS - RTD TRANSMITTER
B5RS - RTD TRANSMITTER Specify Pt100, Pt50, Ni508.4 and temp. range. Special RTD acceptable 12-28 Vdc powered Fast response 25 msec. optional
-
B5TS - THERMOCOUPLE TRANSMITTER
B5TS - THERMOCOUPLE TRANSMITTER Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable 12-28 Vdc powered Fast response 25 msec. optional
-
B3FR - RTD TRANSMITTER
B3FR - RTD TRANSMITTER Pt100, Ni120, Cu10 selectable 12-45 Vdc powered
-
B3FT-1 THERMOCOUPLE TRANSMITTER
B3FT-1 THERMOCOUPLE TRANSMITTER K, J, T or E, R, N selectable 12-45 Vdc powered
-
B6U 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
B6U 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER DC mV, V & mA, T/C, RTD, Pot and resistance input 12-42 Vdc powered (max. 28 V approved) ATEX Zone 0 approval FM Class I, Div. 1 & 2 approval
-
26REX RTD TRANSMITTER
26REX RTD TRANSMITTER Pt100 input. Select temp. range. Non-isolated. 12-30 Vdc powered. ATEX Zone 0 approval
-
26R1 RTD TRANSMITTER
26R1 RTD TRANSMITTER Pt100 input. Select temp. range. Non-isolated. 8.5-32 Vdc powered Economical model
-
26TS1 THERMOCOUPLE TRANSMITTER
26TS1 THERMOCOUPLE TRANSMITTER Specify K, E, J, T, B, R, S, N and temp. range. Special T/C acceptable 12-32 Vdc powered Fast response 25 msec. optional
-
27R RTD TRANSMITTER
27R RTD TRANSMITTER Pt100, Pt1000, Pt500 selectable. Non-isolated. Function monitor LED optional 9-35 Vdc powered ATEX Zone 0 approval FM Class I, Div. 1 & Zone 0 approval
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors