CC-Link INTERFACE MODULE R6-NC3

Share on FacebookShare on Google+Tweet about this on TwitterShare on LinkedIn

Tình trạng: In stock

Contact: 0989649965

R6-NC3 Remote I/O R6 Series CC-Link INTERFACE MODULE

Số lượt xem: 1580

Detail

R6-NC3

Remote I/O R6 Series

CC-Link INTERFACE MODULE
(CC-Link Ver.2.00; for 64-point analog signals)

Functions & Features
• Free combination of analog and discrete I/O
• Direct sensor inputs
• Space-saving
• Low power consumption
Typical Applications
• Remote I/O for DCS and PLC
 

MODEL: R6-NC3[1]

ORDERING INFORMATION
• Code number: R6-NC3[1]
Specify a code from below for [1].
  (e.g. R6-NC3/W/Q)
• Specify the specification for option code /Q
  (e.g. /C01)

[1] OPTIONS (multiple selections)
Dual Network
blank: Unavailable
/W: Available
Other Options
blank: none
/Q: Option other than the above (specify the specification)

SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating

PACKAGE INCLUDES...
• Terminating resistor (110 Ω, 0.5 W)

GENERAL SPECIFICATIONS
Connection
 
 Network: Euro type connector terminal
  (applicable wire size: 0.2 to 2.5 mm2, stripped length
  7 mm)
  Internal bus: Via the Installation Base (model: R6x-BS)
  Internal power: Via the Installation Base (model: R6x-BS)
  (For dual network, be sure to use R6x-BS8B for base.)
Housing material: Flame-resistant resin (gray)
Max. number of I/O modules: 32 (analog 64 points)
Isolation: CC-Link to internal bus or internal power
Dual communication setting: Set with the side DIP switch
Main network module’s operation mode at restart setting: Set with the side DIP switch
RUN indicator: Bi-color (green/red) LED; green in normal communications; red when receiving (Function selected with DIP SW)
ERR indicator: Bi-color (green/red) LED; the green ON/ blinks in communication errors; red when transmitting (Function selected with DIP SW)
Data allocation: Mode 1 or 2 set with the side DIP switch

CC-Link COMMUNICATION
Protocol: CC-Link. Conforms to Version 2.00
(incompatible with Ver.1)
Device type: Remote device station
Required nodes: 4 (112 I/O points, 16 words) × m (m = Cyclic expansion setting)
Network cable: Approved for CC-Link
Cyclic expansion: 2, 4 (Function selected with DIP SW3)
Station No. setting: Rotary switch; 1 to 64
Baud rate setting: Rotary switch
156kbps, 625kbps, 2.5Mbps, 5Mbps, 10Mbps

INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R6x-BS)
Weight: 100 g (3.53 oz)

PERFORMANCE
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute (CC-Link to internal bus or internal power)

STANDARDS & APPROVALS
Refer to the manuals to comply with the standards.
EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
RoHS Directive
  EN 50581

NETWORK REDUNDANT SYSTEM
The dual network system is only available using two (2) interface modules (with option /W). In case that a single interface module is mounted, RUN and ERR indicator LED turn off. Before turn on the power, be sure to mount two interface modules.
The modules must be mounted on a 36.5 mm width base (model: R6x-BS8B). Please, be sure to set always one of the two (2) interface modules’ SW8 as main, and the other one as sub. If the both modules are set as main or both as sub, none of them is operable. When the main network module is in main-operation mode, the sub network module is in sub-operation mode.
The main-operating module is able to transmit input data and to set output data. The sub-operating module is able to input data. However, since the main-operating module has the priority, the sub-operating module is not able to set output data.
In case of communication error, failure or detachment in the main network module, the sub network module takes over the main-operation. When the failed main network module is replaced or its transmission is recovered, its operation mode is selectable with DIP SW.

EXTERNAL VIEW

COMMUNICATION CABLE CONNECTIONS

TRANSMISSION DATA DESCRIPTIONS
The DIP SW located at the side of the module switches the unit’s data allocation mode.
In the Data Allocation Mode 1, one (1) word is assigned per module. The second channel of analog I/O modules cannot be used.
In the Data Allocation Mode 2, two (2) words are assigned per module regardless of whether the second word area is required or not, even for discrete I/O modules that require one (1) word.
A maximum of 32 I/O modules can be mounted per node.
Each Status data is available when the Ready is “1” (the internal bus in normal condition). While the Ready is “0,” all of the Status data is “0” (the internal bus in abnormal condition).

I/O DATA DESCRIPTIONS

EXTERNAL DIMENSIONS unit: mm (inch)

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

M-System Co., Ltd.

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1065652
Online: 9
0989649965
Sales@m-system.com.vnFacebook: M-System.com.vnZalo: 0989649965