MAKN ONE-PORT SURGE PROTECTOR

Share on FacebookShare on Google+Tweet about this on TwitterShare on LinkedIn

Tình trạng: In stock

Contact: 0989649965

Số lượt xem: 1063

Detail

·Some details are not shown. Please refer to specification sheets for all information.

MAKN

Lightning Surge Protectors for
Electronics Equipment M-RESTER

ONE-PORT SURGE PROTECTOR
BETWEEN NEUTRAL AND PROTECTIVE EARTH

Functions & Features
• Designed to protect electronics equipment from induced lightning surges with gas discharge tube
• One-port surge protector according to IEC 61643-1
• Connected between neutral and protective earth
• High discharge current capacity of 40 kA (8/20 μs)
• Protect against overvoltage between N and PE caused by earth fault
• No interruption of power supply even when the head element is removed: easy maintenance and replacing
• Degraded head element is automatically separated from the power lines to prevent overheating, with a relay contact output to alert the failure status
• Head-base connection is keyed so that only a head element of correct line voltage can be mounted
Typical Applications
• Protection between N and PE of TT system
• Low-voltage distribution board
• Combination with installation for large load current
 

MODEL: MAKN–220[1]

ORDERING INFORMATION
• Code number: MAKN-220[1]
Specify a code from below for [1].
  (e.g. MAKN-220/AN)

OPERATIONAL VOLTAGE
220: 220 V AC

[1] OPTIONS
Configuration
Blank: With alarm output
/AN: Without alarm output
/BN: Head element for replacement

RELATED PRODUCTS
• One-port surge protector for power supply use (model: MAKF)
• Single mount adaptor (model: MBS)
• Wiring bridge (model: CNB)

GENERAL SPECIFICATIONS
Construction: Plug-in
Degree of protection: IP20 (If the solderless terminals are covered with insulation tubes.)
Surge protection type: Voltage switching type one-port SPD (IEC 61643-1)
Discharge element: Gas discharge tube
Connection
  Line: M5 screw terminal (spring up-screw type)
(torque: 2.5 N·m)
  Alarm output: Euro type connector terminal
(torque: 0.25 N·m)
Applicable wire size
 Line connection: 
See the sloderless terminal drawing.
 Alarm output: 0.14 to 1.5 mm2, stripped length 7 mm
Housing material: Flame-resistant resin (black)
Alarm output: The SPDT relay trips when the thermal breaker operates and/or the head element is removed.
Rated load: 250 V AC @0.5 A (resistive load)
125 V DC @0.2 A (resistive load)
Minimum switching load: 5 V DC, 1 mA
Line voltage identification key: The connection of the head element and the base is keyed for exact matching.
Safety function: Thermal breaker incorporated
Failure indicator: The check window color changes from green (normal) to black (failed and the thermal breaker separated the M-rester from the circuit).

INSTALLATION
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: DIN rail; Surface mounting available with the Single Mount Adaptor model: MBS.
Weight: 100 g (3.53 oz)

PERFORMANCE
Response time: ≤ 100 nsec
Maximum discharge current: 40 kA (8/20 μsec.)
Nominal discharge current: 20 kA (8/20 μsec.)
TOV value: 1200 V/0.2 sec.
Insulation resistance: ≥ 100 MΩ with 500 V DC
(N or PE to alarm output)
Dielectric strength: 2000 V AC @1 minute
(N or PE to alarm output)
Surge protection: IEC 61643-1 Class II
Leakage current: ≤ 100 μA at the discharge voltages listed in the table below.

CONNECTION EXAMPLES

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

M-System Co., Ltd.

PRODUCTS LIST

News Product

WL40VN Series - 920 MHz Band Wireless I/O (for use in Vietnam)
Wireless Tower Light (FCC Part 15 compliant wireless module) IT40SW5F/6F, IT50SW5F/6F, IT60SW5F/6F Series
TR30-G Tablet Recorder  Web-enabled DAQ System
News

STATISTIC

Visitor: 1057502
Online: 23
0989649965
Sales@m-system.com.vnFacebook: M-System.com.vnZalo: 0989649965