40DT THERMOCOUPLE INPUT DIGITAL PANEL METER
Tình trạng: In stock
Contact: 0989649965
40DT Digital Panel Meters 40 Series
Số lượt xem: 1424
Detail
40DT
Digital Panel Meters 40 Series
THERMOCOUPLE INPUT DIGITAL PANEL METER
(4 digits, process meter)
Functions & Features
• 4 digit (±9999) panel meter
• HOLD functions
• High visible, 0.8" (20.3mm) high and bright LED
MODEL: 40DT–T1–[1][2]
ORDERING INFORMATION
• Code number: 40DT–T1–[1][2]
Specify a code from below for each [1] and [2].
(e.g. 40DT-T1-R/Q)
• Specify the specification for option code /Q
(e.g. /C01/SET)
INPUT
T1:
K (CA) (Usable range -150 to +1370°C, -238 to +2498°F)
J (IC) (Usable range -180 to +1000°C, -292 to +1832°F)
T (CC) (Usable range -170 to +400°C, -274 to +752°F)
R (Usable range 380 to 1760°C, 716 to 3200°F)
[1] POWER INPUT
AC Power
K3: 100 – 120V AC
(Operational voltage range 85 - 132 V, 47 - 66 Hz)
L3: 200 – 240V AC
(Operational voltage range 170 - 264 V, 47 - 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±20 %, ripple 10 %p-p max.)
[2] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
Moving parts and indicators are not coated.
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
(No. ESU-9535)
GENERAL SPECIFICATIONS
Construction: Panel flush mounting
Connection: M3 screw terminals (torque 0.6 N·m)
Solderless terminal: Refer to the drawing at the end of the section.
Recommended manufacturer: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd
Applicable wire size: 0.25 to 1.65 mm2 (AWG 22 to 16)
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (gray)
Isolation: Input to power
Cold junction compensation: CJC sensor attached to the
input terminals
A/D conversion: Σ – Δ
Sampling rate: 10 times/sec. (100 msec.)
Averaging: None or moving average
Setting: (Front button)
• Input type
• Temperature unit
• Moving average
• Brightness
• Others
DISPLAY
Display: 4 digits of 20.3 mm (0.8 inch) height, 7-segment, red LED
Display range: -9999 to 9999
Minimum display/setting scale: 1°C or 1°F
Zero indication: Higher-digit zeros are suppressed.
Over-range indication:
'S.ERR' blinks surpassing the permissible range.
'B.ERR' blinks at burnout.
Engineering unit indication: Sticker label attached
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
cm, mm, m, m/sec, mm/min, cm/min, m/min,
m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec,
m3/min, m3/h, Nm3/h, N·m, N/m2, g, kg, kg/h,
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,
kJ, MJ, rpm, sec, min, pH, %, ppm, etc.
INPUT SPECIFICATIONS
■ Thermocouple
Input resistance: 1 MΩ minimum
Burnout sensing: ≤ 0.1 μA
Usable range (conformance range):
K (CA) -150 to +1370℃ or -238 to +2498°F
J (IC) -180 to +1000℃ or -292 to +1832°F
T (CC) -170 to +400℃ or -274 to +752°F
R 380 to 1760℃ or 716 to 3200°F
Operational range:
K (CA) -180 to +1400℃ or -292 to +2552°F
J (IC) -210 to +1030℃ or -346 to +1886°F
T (CC) -200 to + 430℃ or -328 to +806°F
R 170 to 1790℃ or 338 to 3254°F
■ Hold Input: Dry contact input
Detecting level: ≤ 1.5 V
Sensing: Approx. 5 V DC, 1 mA
INSTALLATION
Power consumption
•AC: Approx. 1.0 VA
•DC: Approx. 0.3 W
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Panel flush mounting
Weight: 210 g (0.46 lb)
PERFORMANCE
Accuracy
K narrow range (-150 – +400°C, -238 – +752°F ):
±1°C rdg ± 1digit, ±2°F rdg ± 1digit
K wide range (400 – 1370°C, 752 – 2498°F):
±3℃ rdg ± 1digit, ±6°F rdg ± 1digit
J: ±1℃ rdg ± 1digit, ±2°F rdg ± 1digit
T: ±1℃ rdg ± 1digit, ±2°F rdg ± 1digit
R: ±3℃ rdg ± 1digit, ±6°F rdg ± 1digit
Cold junction compensation error:
±3°C at 25 ±10°C
±5.4°F at 77 ±18°F
Temp. coefficient: ±0.1 ℃/℃
Line voltage effect: ±2 digits over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @1 minute (input to power to ground)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II
Pollution Degree 2
Input to power: Reinforced insulation (300 V)
RoHS Directive
EN 50581
DISPLAY HOLD COMMAND
Displayed value is held with an external HOLD command input. Connect the contacts across HOLD to COM.
EXTERNAL VIEW
PARAMETER LIST
DIMENSIONS unit: mm (inch)
PANEL CUTOUT unit: mm
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
M-System Co., Ltd.
Products
-
43AL1 LOOP POWERED DIGITAL PANEL METER
43AL1 Digital Panel Meters 43 Series
-
43DV2 DC INPUT DIGITAL PANEL METER
43DV2 Digital Panel Meters 43 Series
-
40LV DC INPUT DIGITAL PANEL METER
40LV Digital Panel Meters 40 Series
-
40DV DC INPUT DIGITAL PANEL METER
40DV Digital Panel Meters 40 Series
-
40DR RTD INPUT DIGITAL PANEL METER
40DR Digital Panel Meters 40 Series
-
40DPT AC VOLTAGE INPUT DIGITAL PANEL METER
40DPT Digital Panel Meters 40 Series
-
40DN LOOP POWERED DIGITAL PANEL METER
40DN Digital Panel Meters 40 Series
-
40DCT AC CURRENT INPUT DIGITAL PANEL METER
40DCT Digital Panel Meters 40 Series
-
43AL1-B LOOP POWERED DIGITAL METER
43AL1-B Digital Panel Meters 43 Series
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC