Sắp xếp |
-
M6SPA M6XPA M6DPA FREQUENCY TRANSMITTER
M6SPA M6XPA M6DPA FREQUENCY TRANSMITTER Open collector, mechanical contact, 5V/24V pulse. Specific input range up to 100 kHz 24 Vdc powered
-
M5PA FREQUENCY TRANSMITTER
M5PA FREQUENCY TRANSMITTER Open collector, mechanical contact, 5V/12V/24V pulse. Specific input range up to 100 kHz 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
-
W5PA FREQUENCY TRANSMITTER
W5PA FREQUENCY TRANSMITTER Open collector, mechanical contact, 5V/12V/24V pulse. Specific input range up to 100 kHz Independent output ranges selectable 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type)
-
M2AP DC/FREQUENCY CONVERTER
M2AP DC/FREQUENCY CONVERTER Specific input range up to 300 V Open collector, 5V pulse or mercury relay output. Specific output range up to 1 kHz. 100-240 Vac or 24 Vdc powered UL/cUL Class I, Div. 2 approval
-
W2AP DC/FREQUENCY CONVERTER
W2AP DC/FREQUENCY CONVERTER Specific input range up to 300 V Open collector, 5V pulse or mercury relay output. Specific output range up to 10 kHz. 100-240 Vac or 24 Vdc powered. UL/cUL Class I, Div. 2 approval
-
M3LM POTENTIOMETER TRANSMITTER
M3LM POTENTIOMETER TRANSMITTER Potentiometer 90-20k ohms Output selectable within 0-20 mA and ±10 V 10-32 Vdc powered DIP switch or PC configuration 125-point linearization using the PC Configurator
-
M3LV SIGNAL TRANSMITTER
M3LV SIGNAL TRANSMITTER Input selectable within 0-20 mA and ±10 V Output selectable within 0-20 mA and ±10 V 10-32 Vdc powered DIP switch or PC configuration
-
M6SDY CURRENT LOOP SUPPLY
M6SDY , M6NDY M6DDY CURRENT LOOP SUPPLY 4-20 mA input Supply output 24-30V @22 mA Signal output 4-20 mA, 0-10 V, 0-5 V, 1-5 V 24 Vdc powered
-
M2PP PULSE ISOLATOR
M2PP PULSE ISOLATOR Mechanical contact, open collector or voltage pulse input; 0-10 kHz max. Open collector, voltage pulse or mercury relay output 100-240 Vac or 24 Vdc powered UL Class I, Div. 2 approval
-
YPD PULSE ISOLATOR
YPD PULSE ISOLATOR Dry contact, voltage pulse or two-wire current input; 0-100 kHz max. Excitation 5 V or 12 V Open collector, voltage pulse or relay contact output 100, 110, 115, 120, 200, 220, 240 Vac or 12, 24, 48 Vdc powered
-
M2XRP2 ENCODER SPEED TRANSMITTER
M2XRP2 ENCODER SPEED TRANSMITTER Converts a two-phase forward and reverse rotation pulse signal with 90 degree phase difference into a forward and reverse speed signal. Open collector, voltage pulse, RS-422 line driver selectable; 0-100 kHz max. Excitation 5 V or 12 V selectable Output selectable within 0-20 mA and ±10 V 100-240 Vac or 24 Vdc powered
-
JRP2 ENCODER SPEED TRANSMITTER
JRP2 ENCODER SPEED TRANSMITTER Converts a two-phase forward and reverse rotation pulse signal with 90 degree phase difference into a forward and reverse speed signal. Open collector, voltage pulse or RS-422 line driver pulse inputs Excitation 5 V, 12 V or 24 V 85-132 Vac or 12, 24, 48, 110 Vdc powered Applications: Measuring moving speed of a machine with a rotary encoder
JRP2 ENCODER SPEED TRANSMITTER
-
JRQ2 ENCODER POSITION TRANSMITTER
JRQ2 ENCODER POSITION TRANSMITTER JRQ2 Converts a two-phase forward and reverse rotation pulse signal with 90 degree phase difference into a forward and reverse position signal. Open collector, voltage pulse or RS-422 line driver pulse inputs Excitation 5 V, 12 V or 24 V 85-132 Vac or 12, 24, 48, 110 Vdc powered Applications: Measuring moving distance of a machine with a rotary encoder
-
RPPD PULSE ISOLATOR
RPPD PULSE ISOLATOR Galvanically isolates two pulse rate signals from a rotary encoder. Dry contact, voltage pulse, two-wire current pulse, or RS-422 line driver pulse inputs. Relay, open collector or voltage pulse outputs Excitation 5 V, 12 V or 24 V 85-132 Vac or 12, 24, 48, 110 Vdc powered Applications: Isolating field pulse signals in order to reduce noise interference
-
M2D2 CURRENT LOOP SUPPLY
M2D2 CURRENT LOOP SUPPLY 4-20 mA input Supply output 24 V @30 mA Signal output 4-20 mA and 1-5 V 100-240 Vac or 24 Vdc powered
-
M5DY CURRENT LOOP SUPPLY
M5DY CURRENT LOOP SUPPLY 4-20 mA input Supply output 24-28 V @22 mA Signal output 4-20 mA and other voltage or current range 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type) Economical model
-
W5DY CURRENT LOOP SUPPLY
W5DY CURRENT LOOP SUPPLY 4-20 mA input Supply output 24-28 V @22 mA Signal output 4-20 mA and other voltage or current range Independent output ranges selectable 100-240 Vac or 24 Vdc powered (CE for 24 Vdc type
-
M3DY CURRENT LOOP SUPPLY
M3DY CURRENT LOOP SUPPLY 4-20 mA input Supply output 24-28 V @22 mA Signal output 4-20 mA and other voltage or current range 100-240 Vac or 24 Vdc powered
-
M3SDY-AA
M3SDY CURRENT LOOP SUPPLY 4-20 mA input Supply output 24-28 V @22 mA Signal output 4-20 mA and other voltage or current range 24 Vdc powered
-
MDC5 DC POWER SUPPLY
MDC5 DC POWER SUPPLY 100-240 Vac input Supply output 24 V -10/+15% Max. load current 2.5 A Maintenance forecast monitor function
-
MDC6 DC POWER SUPPLY
MDC6 DC POWER SUPPLY 100-240 Vac input Supply output 24 V -10/+15% Max. load current 5 A Maintenance forecast monitor function
-
M2DNY CURRENT LOOP SUPPLY
M2DNY CURRENT LOOP SUPPLY 4-20 mA input Supply output 24-28 V @22 mA Signal output 4-20 mA and other voltage or current range 100-240 Vac or 24 Vdc powered Low-end cutout
-
M2PRU PULSE SCALER
M2PRU PULSE SCALER Open collector, mechanical contact, 5V pulse or two-wire current pulse input; 0-100 kHz max. Excitation 12 V/24 V @30mA Open collector, voltage pulse, AC/DC switch output Scaling factor adjustable of 1.000 x 1/1 to 0.0001 x 1/1000000 100-240 Vac or 24 Vdc powered UL/cUL Class I, Div. 2 approval
M2PRU PULSE SCALER
-
M2CE CURRENT TRANSMITTER
M2CE CURRENT TRANSMITTER 0-1 A or 0-5 A 100-240 Vac or 24 Vdc powered UL/cUL Class I, Div. 2 approval
PRODUCTS LIST
- Signal Conditioners
- 2-wire Signal Conditioners
- Power Transducers
- Indicators
- Tower Lights
- Limit Alarms
- Gateway, Remote IO
- Paperless Recording System
- PC Recorder
- Web Data Loggers
- PID Control Components
- BA&Energy Monitoring Components
- Temperature Controllers
- Electric Actuators
- Lightning Surge Protectors
STATISTIC
Visitor: 1056761Online: 22